Kinematics

In subindex 30 and subindex 31, the main axis and the following axis can be assigned to the single-axis kinematics. By selecting the coupling mode in subindex 35, it is determined which values of the main axis are used as setpoints for the following axis. The control mode parameterized in the following axis has no influence on the coupling values when coupling is active.

Coupling mode Position absolute (Subindex 35 = 0)

  • For operation in absolute coupling mode, both axes must be homed (exception: homing\Homing). If this is not the case, the axes cannot be moved and a warning is output in the main axis.

  • The target position, target speed and target acceleration of the main axis are used as setpoints for the following axis.

  • If the main axis performs an application quick stop or an active error reaction, the actual position is used as setpoint for the following axis instead of the target position.

 

Signal flow diagram:

 

Coupling mode Position relative (Subindex 35 = 1)

  • For operation in relative coupling mode, the axes do not need to be homed

  • The target position, target speed and target acceleration of the main axis are used as setpoints for the following axis.

  • If the main axis performs an application quick stop or an active error reaction, the actual position is used as setpoint for the following axis instead of the target position.

     

Signal flow diagram:

 

Coupling mode Torque support (Subindex 35 = 2)

  • The following axis follows the target speed of the main drive

  • The integral component of the speed controller is deactivated

  • The actual torque of the main drive is used as torque feedforward for the following axis

 

Signal flow diagram:

 

Coupling mode Torque control (Subindex 35 = 3)

  • The following axis follows the actual torque of the main drive

  • The speed clamps of the following drive are set to 1.2 times the target speed of the main drive

 

Signal flow diagram:

 

The table below lists the combinations of coupling modes and control modes and shows which setpoints of the main axis are used for the following axis.

  Coupling mode Control mode Main axis Control mode Following axis (parameterized) Control mode Following axis (parameterized) Coupling value position Coupling value speed
1 Position absolute PosCtrl Motor PosCtrl Motor - Target position*1 Target speed
2 Position absolute PosCtrl Motor PosCtrl PLC - Target position*1 Target speed
3 Position absolute PosCtrl Motor VelCtrl - - Target speed
4 Position absolute PosCtrl PLC PosCtrl Motor - Target position*1 Target speed
5 Position absolute PosCtrl PLC PosCtrl PLC - Target position*1 Target speed
6 Position absolute PosCtrl PLC VelCtrl - - Target speed
7 Position absolute VelCtrl PosCtrl Motor - Target position*1 Target speed
8 Position absolute VelCtrl PosCtrl PLC - Target position*1 Target speed
9 Position absolute VelCtrl VelCtrl - - Target speed
10 Position absolute Torque (FB) PosCtrl Motor - Actual position Actual speed
11 Position absolute Torque (FB) PosCtrl PLC - Actual position Actual speed
12 Position absolute Torque (FB) VelCtrl - - Actual speed
13 Position relative PosCtrl Motor PosCtrl Motor - Target position differences*1 Target speed
14 Position relative PosCtrl Motor PosCtrl PLC - Target position differences*1 Target speed
15 Position relative PosCtrl Motor VelCtrl - - Target speed
16 Position relative PosCtrl PLC PosCtrl Motor - Target position differences*1 Target speed
17 Position relative PosCtrl PLC PosCtrl PLC - Target position differences*1
18 Position relative PosCtrl PLC VelCtrl - -
19 Position relative VelCtrl PosCtrl Motor - Target position differences*1
20 Position relative VelCtrl PosCtrl PLC - Target position differences*1
21 Position relative VelCtrl VelCtrl -  
22 Position relative Torque (FB) PosCtrl Motor - Actual position Actual speed
23 Position relative Torque (FB) PosCtrl PLC - Actual position
24 Position relative Torque (FB) VelCtrl - Actual position
24 Torque support PosCtrl Motor PosCtrl Motor VelCtrl - Target speed
25 Torque support PosCtrl Motor PosCtrl PLC VelCtrl -
26 Torque support PosCtrl Motor VelCtrl VelCtrl -
27 Torque support PosCtrl PLC PosCtrl Motor VelCtrl -
28 Torque support PosCtrl PLC PosCtrl PLC VelCtrl -
29 Torque support PosCtrl PLC VelCtrl VelCtrl -
30 Torque support VelCtrl PosCtrl Motor VelCtrl -
31 Torque support VelCtrl PosCtrl PLC VelCtrl -
32 Torque support VelCtrl VelCtrl VelCtrl -
33 Torque support Torque (FB) PosCtrl Motor VelCtrl - Actual speed
34 Torque support Torque (FB) PosCtrl PLC VelCtrl -
35 Torque support Torque (FB) VelCtrl VelCtrl -
35 Torque control PosCtrl Motor PosCtrl Motor Torque - Clamp = 1.2*Target speed
36 Torque control PosCtrl Motor PosCtrl PLC Torque -
37 Torque control PosCtrl Motor VelCtrl Torque -
38 Torque control PosCtrl PLC PosCtrl Motor Torque -
39 Torque control PosCtrl PLC PosCtrl PLC Torque -
40 Torque control PosCtrl PLC VelCtrl Torque -
41 Torque control VelCtrl PosCtrl Motor Torque -
42 Torque control VelCtrl PosCtrl PLC Torque -
43 Torque control VelCtrl VelCtrl Torque -
44 Torque control Torque (FB) PosCtrl Motor Torque -
45 Torque control Torque (FB) PosCtrl PLC Torque -
46 Torque control Torque (FB) VelCtrl Torque -

*1 Actual position during QSP application or an active error reaction