Kinematics
In subindex 30 and subindex 31, the main axis and the following axis can be assigned to the single-axis kinematics. By selecting the coupling mode in subindex 35, it is determined which values of the main axis are used as setpoints for the following axis. The control mode parameterized in the following axis has no influence on the coupling values when coupling is active.
Coupling mode Position absolute (Subindex 35 = 0)
-
For operation in absolute coupling mode, both axes must be homed (exception: homing\Homing). If this is not the case, the axes cannot be moved and a warning is output in the main axis.
-
The target position, target speed and target acceleration of the main axis are used as setpoints for the following axis.
-
If the main axis performs an application quick stop or an active error reaction, the actual position is used as setpoint for the following axis instead of the target position.
Signal flow diagram:
Coupling mode Position relative (Subindex 35 = 1)
-
For operation in relative coupling mode, the axes do not need to be homed
-
The target position, target speed and target acceleration of the main axis are used as setpoints for the following axis.
-
If the main axis performs an application quick stop or an active error reaction, the actual position is used as setpoint for the following axis instead of the target position.
Signal flow diagram:
Coupling mode Torque support (Subindex 35 = 2)
-
The following axis follows the target speed of the main drive
-
The integral component of the speed controller is deactivated
-
The actual torque of the main drive is used as torque feedforward for the following axis
Signal flow diagram:
Coupling mode Torque control (Subindex 35 = 3)
-
The following axis follows the actual torque of the main drive
-
The speed clamps of the following drive are set to 1.2 times the target speed of the main drive
Signal flow diagram:
The table below lists the combinations of coupling modes and control modes and shows which setpoints of the main axis are used for the following axis.
| Coupling mode | Control mode Main axis | Control mode Following axis (parameterized) | Control mode Following axis (parameterized) | Coupling value position | Coupling value speed | |
|---|---|---|---|---|---|---|
| 1 | Position absolute | PosCtrl Motor | PosCtrl Motor | - | Target position*1 | Target speed |
| 2 | Position absolute | PosCtrl Motor | PosCtrl PLC | - | Target position*1 | Target speed |
| 3 | Position absolute | PosCtrl Motor | VelCtrl | - | - | Target speed |
| 4 | Position absolute | PosCtrl PLC | PosCtrl Motor | - | Target position*1 | Target speed |
| 5 | Position absolute | PosCtrl PLC | PosCtrl PLC | - | Target position*1 | Target speed |
| 6 | Position absolute | PosCtrl PLC | VelCtrl | - | - | Target speed |
| 7 | Position absolute | VelCtrl | PosCtrl Motor | - | Target position*1 | Target speed |
| 8 | Position absolute | VelCtrl | PosCtrl PLC | - | Target position*1 | Target speed |
| 9 | Position absolute | VelCtrl | VelCtrl | - | - | Target speed |
| 10 | Position absolute | Torque (FB) | PosCtrl Motor | - | Actual position | Actual speed |
| 11 | Position absolute | Torque (FB) | PosCtrl PLC | - | Actual position | Actual speed |
| 12 | Position absolute | Torque (FB) | VelCtrl | - | - | Actual speed |
| 13 | Position relative | PosCtrl Motor | PosCtrl Motor | - | Target position differences*1 | Target speed |
| 14 | Position relative | PosCtrl Motor | PosCtrl PLC | - | Target position differences*1 | Target speed |
| 15 | Position relative | PosCtrl Motor | VelCtrl | - | - | Target speed |
| 16 | Position relative | PosCtrl PLC | PosCtrl Motor | - | Target position differences*1 | Target speed |
| 17 | Position relative | PosCtrl PLC | PosCtrl PLC | - | Target position differences*1 | |
| 18 | Position relative | PosCtrl PLC | VelCtrl | - | - | |
| 19 | Position relative | VelCtrl | PosCtrl Motor | - | Target position differences*1 | |
| 20 | Position relative | VelCtrl | PosCtrl PLC | - | Target position differences*1 | |
| 21 | Position relative | VelCtrl | VelCtrl | - | ||
| 22 | Position relative | Torque (FB) | PosCtrl Motor | - | Actual position | Actual speed |
| 23 | Position relative | Torque (FB) | PosCtrl PLC | - | Actual position | |
| 24 | Position relative | Torque (FB) | VelCtrl | - | Actual position | |
| 24 | Torque support | PosCtrl Motor | PosCtrl Motor | VelCtrl | - | Target speed |
| 25 | Torque support | PosCtrl Motor | PosCtrl PLC | VelCtrl | - | |
| 26 | Torque support | PosCtrl Motor | VelCtrl | VelCtrl | - | |
| 27 | Torque support | PosCtrl PLC | PosCtrl Motor | VelCtrl | - | |
| 28 | Torque support | PosCtrl PLC | PosCtrl PLC | VelCtrl | - | |
| 29 | Torque support | PosCtrl PLC | VelCtrl | VelCtrl | - | |
| 30 | Torque support | VelCtrl | PosCtrl Motor | VelCtrl | - | |
| 31 | Torque support | VelCtrl | PosCtrl PLC | VelCtrl | - | |
| 32 | Torque support | VelCtrl | VelCtrl | VelCtrl | - | |
| 33 | Torque support | Torque (FB) | PosCtrl Motor | VelCtrl | - | Actual speed |
| 34 | Torque support | Torque (FB) | PosCtrl PLC | VelCtrl | - | |
| 35 | Torque support | Torque (FB) | VelCtrl | VelCtrl | - | |
| 35 | Torque control | PosCtrl Motor | PosCtrl Motor | Torque | - | Clamp = 1.2*Target speed |
| 36 | Torque control | PosCtrl Motor | PosCtrl PLC | Torque | - | |
| 37 | Torque control | PosCtrl Motor | VelCtrl | Torque | - | |
| 38 | Torque control | PosCtrl PLC | PosCtrl Motor | Torque | - | |
| 39 | Torque control | PosCtrl PLC | PosCtrl PLC | Torque | - | |
| 40 | Torque control | PosCtrl PLC | VelCtrl | Torque | - | |
| 41 | Torque control | VelCtrl | PosCtrl Motor | Torque | - | |
| 42 | Torque control | VelCtrl | PosCtrl PLC | Torque | - | |
| 43 | Torque control | VelCtrl | VelCtrl | Torque | - | |
| 44 | Torque control | Torque (FB) | PosCtrl Motor | Torque | - | |
| 45 | Torque control | Torque (FB) | PosCtrl PLC | Torque | - | |
| 46 | Torque control | Torque (FB) | VelCtrl | Torque | - |
*1 Actual position during QSP application or an active error reaction