Standard setpoint source
The selected "setpoint source" serves to provide the inverter with its setpoint. The setpoint source can be selected individually for each operating mode.
Possible setpoint sources are:
–
Analog inputs
–
Keypad
–
Network
–
Parameterisable setpoints (presets)
–
"Motor potentiometer" function
–
"Sequencer" function
Details
–
For applications only requiring one setpoint, it is sufficient to define the standard setpoint source in 0x2860:001 (P201.01).
–
For applications requiring a change-over of the setpoint source during operation,
the functions for setpoint change-over have to be configured accordingly.
Changing the setpoint source during operation
Changing the setpoint source during operation Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2860:001
(P201.01)
|
Frequency control: Default setpoint source
(Freq. setp. src.)
|
Selection of the standard setpoint source for operating mode "MS: Velocity mode".
–
The selected standard setpoint source is always active in the operating mode 0x6060 (P301.00) = "MS: Velocity mode [-2]" when no setpoint change-over to another setpoint source via corresponding triggers/functions is active.
|
|
|
1
|
Keypad
|
The setpoint is specified locally by the keypad.
–
Default setting: 0x2601:001 (P202.01)
–
Use the and navigation keys to change the keypad setpoint (also during running operation).
|
|
|
2
|
Analog input 1
|
The setpoint is defined as analog signal via the analog input 1.
|
|
|
3
|
Analog input 2
|
The setpoint is defined as analog signal via the analog input 2.
|
|
|
5
|
Network
|
The setpoint is defined as process data object via the network.
|
|
|
11
|
Frequency preset 1
|
For the setpoint selection, preset values can be parameterised and selected.
|
|
|
12
|
Frequency preset 2
|
||
|
13
|
Frequency preset 3
|
||
|
14
|
Frequency preset 4
|
||
|
15
|
Frequency preset 5
|
||
|
16
|
Frequency preset 6
|
||
|
17
|
Frequency preset 7
|
||
|
18
|
Frequency preset 8
|
||
|
19
|
Frequency preset 9
|
||
|
20
|
Frequency preset 10
|
||
|
21
|
Frequency preset 11
|
||
|
22
|
Frequency preset 12
|
||
|
23
|
Frequency preset 13
|
||
|
24
|
Frequency preset 14
|
||
|
25
|
Frequency preset 15
|
||
|
31
|
Segment preset 1
|
For the setpoint selection, the segment presets parameterised for the "sequencer" function can be selected as well.
|
|
|
32
|
Segment preset 2
|
||
|
33
|
Segment preset 3
|
||
|
34
|
Segment preset 4
|
||
|
35
|
Segment preset 5
|
||
|
36
|
Segment preset 6
|
||
|
37
|
Segment preset 7
|
||
|
38
|
Segment preset 8
|
||
|
50
|
Motor potentiometer
|
The setpoint is generated by the "motor potentiometer" function. This function can be used as an alternative setpoint control which is controlled via two signals: "MOP setpoint up" and "MOP setpoint down".
|
|
|
201
|
Internal value
|
Internal values of the manufacturer.
|
|
|
202
|
Internal value
|
||
|
203
|
Internal value
|
||
|
204
|
Internal value
|
||
|
205
|
Internal value
|
||
|
206
|
Internal value
|
||
Changing the setpoint source during operation
and
navigation keys to change the keypad setpoint (also during running operation).