L_IE1P_Reaction

For the severity levels (L_IE1P_Severity):
  • Information

  • Warning

  • Warning_Lock

  • Fault_Log

  • Fault

an additional reaction can be defined. This can be used in the application to map different behaviours for an identical severity level.

For some reactions, automatisms already exist if an axis or axis group is connected as an error handler.

The prioritisation of the reaction with the same severity is based on the enum value. The higher the value, the higher the priority.

Selection

Value

Reaction
Axis_Ref

Reaction

virt. Axis_Ref

Reaction

Axes_Group

No_Response

0

None

None

None

UserReaction1

1

No predefined function

No predefined function

No predefined function

UserReaction2

2

No predefined function

No predefined function

No predefined function

CycleStop

3

No predefined function

No predefined function

No predefined function

NormalStop

4

No predefined function

No predefined function

No predefined function

FastStop

5

No predefined function

No predefined function

No predefined function

UserReaction6

6

No predefined function

No predefined function

No predefined function

QspAppl

11

Stop with QSP Appl. Ramp (Sub/48+49), drive remains enabled

Stop with QSP Appl. Ramp (Sub/48+49), drive remains enabled

Stop the connected drives with QSP Appl. Ramp (Sub/48+49), drive remains enabled

Qsp

12

Stop with QSP Drive Ramp (0x6085/0), drive remains enabled

Stop with QSP Appl. Ramp (Sub/48+49), drive remains enabled

Stop the connected drives with QSP Drive Ramp (0x6085/0), drive remains enabled

Qsp_Cinh

13

Stop with QSP Drive Ramp (0x6085/0), after reaching standstill, the drive is disabled.

QSPAPPL, then Axis_Enabled changes to False

Stop with QSP Drive Ramp (0x6085/0), after reaching standstill, the drive is disabled.

Cinh

14

drive controller inhibit immediately

Axis_Enabled changes to False

Inhibit all axes