A slave does not accept a cyclic frame

In the Operational state, the process data is exchanged cyclically.
If a slave does not accept the cyclical frame (WKC is not increased), this error is caused.
Cause
–
The bus cable between two EtherCAT devices has been unplugged.
 
–
The node at position X is deenergised.
 
–
A slave no longer receives cyclical frames, such that the watchdog determined by the device description is triggered. This message will usually only be transmitted if the connection to the master has been re-established.
 
Error message
–
EtherCAT_Master: Not all slaves 'Operational' (repeated 100 times)
 
–
EtherCAT_Master: Not all slaves 'Operational' (repeated 10 times)
 
–
EtherCAT_Master: Cyclic command WKC error (repeated 10 times) [DeviceName] (1002): Communication to device interrupted
 
–
EtherCAT_Master: Not all slaves 'Operational' (repeated 1 time)
 
–
EtherCAT_Master: Cyclic command WKC error (repeated 1 time)
 
–
EtherCAT_Master: Cyclic command WKC error (repeated 100 times)
 
Remedies
Correct bus topology and restart the EtherCAT fieldbus. Restart network