Response times of the safety unit

The overall system must be taken into account when determining the response time following a safety function request.
 
Decisive for the reaction time are:
–
Response time of the connected safety sensors.
 
–
Input delay of the safety inputs.
 
–
Internal processing time.
 
–
Deceleration times, braking times, and stopping times from the parameterized safety functions.
 
–
When a feedback system is used:
 
–
The response time of encoder monitoring. 0x2878:004
 
 
–
When a safety bus is used:
 
–
Monitoring time for cyclic services.
 
–
Monitoring time in the safety PLC.
 
–
Processing time in the safety PLC.
 
 
–
Delay times due to further components.
 
Fig. 1: Response times to the request of a safety function
1
Standard device 
 
2
Integrated safety 
 
3
Safety PLC 
 
4
Safety bus 
 
μC
Microcontroller 
 
S
Safety sensors 
 
SF
Activated safety function 
 
SBC
Safe Brake Control 
 
 
 
Response times of safe inputs
Response time to an event in the safety sensors
[ms]
t1
Response time of the safety sensors
according to manufacturer information
t2
Input delay of the safe inputs
Parameterizable via:
0...100
Input filter
2
ti
Processing time in drive-based safety sensor technology
4
Safety function starts after
t1 + t2 + ti
Tab. 1: Response time to an event in the safety sensors
 
Response time of the safe output
Response time of the safe output to a safety function
[ms]
Safe output SD-Out 1 switches to
4
Tab. 2: Response time - safe output
 
Response time of encoder monitoring
Time required to detect faults caused by continuous signal errors at the encoder interface.
[ms]
Default setting
50
Parameterizable via:
12/50/100
It must be evaluated for each application what minimum response time is possible.
The longer the reaction time, the more the safe speed is filtered.
During dynamic processes (acceleration, deceleration), the safely evaluated speed (nSD) lags behind the actual speed of the drive (nBD) (displayed in 0x287B:006). This time offset must be taken into account when reaching limit values.
 
 
Response times of safe SBC brake control
Response time from the detection of the SBC safety function to the switch-off of the safe brake control
[ms]
tbr
Delay time between request and activation of the brake control
Parameterizable via:
0 ... 30000
ti
Processing time in drive-based safety sensor technology
4
Control X106 starts after
tbr + ti
Test pulse interval and error response time
[ms]
Test pulse interval, brake control
100
Error response time, min. time for error detection and error triggering
200
 
Response times of the safety bus
Response time to an event on the safety sensors (input data)
[ms]
t1
Response time of the safety sensors
See manufacturer information
t2
Input delay of the safe inputs
Parameterizable via:
0...100
Input filter
2
t3
Processing time in integrated safety technology
Main Task cycle time
Technology application
1
PLC project
As set
Internal transmission time PROFIsafe
Safety: from firmware 1.0.1
Standard device: from firmware 1.2
40
Internal transmission time FSoE
Safety: from firmware 1.1.x
Standard device: from firmware 1.3
8
Input data ready for transmission
t1 + t2 + t3
tps
PROFINET cycle time
See project planning in the PLC
EtherCAT cycle time
Input data ready for processing in the safety PLC
t1 + t2 + t3 + tps
Tab. 3: Response time to an event on the safety sensors
Response time to a control word (output data)
[ms]
t4
Processing time in the safety PLC
Calculate
tps
PROFINET cycle time
See project planning in the PLC
EtherCAT cycle time
t5
Processing time in integrated safety technology
Main Task cycle time
Technology application
1
PLC project
As set
Internal transmission time PROFIsafe
Safety: from firmware 1.0.1
Standard device: from firmware 1.2
108
Internal transmission time FSoE
Safety: from firmware 1.1.x
Standard device: from firmware 1.3
16
Safety function starts after
t4 + tps + t5
Tab. 4: Response time for request via the safety bus
Information on how to calculate the processing time and transmission time of the safety bus can be found in the documentation of the safety PLC used.
When the safety bus communication is disturbed, it is changed to the fail-safe state after the safety bus monitoring time (F_WD_Time) has elapsed. The safety bus communication is passivated.
 
Example
–
After an event at a safe input, the message is fed back to the integrated safety technology via the safety PLC.
 
–
The integrated safety technology then triggers a safety function.
 
–
The maximum response time to the event is then calculated to:
 
–
tmax = t1 + t2 + t3 + max (F_WD_Time; tps + t4 + tps + t5)
 
–
Include the times of the safety functions
in the calculation, e.g. for SS1 the stop time until STO is active. 0x2894:001