Mark failure detection
If the output is set via bit 23 in the Status signals parameter, no mark was detected within the configured mark window.
0x5040:110 Bit 23
0x5040:110 Bit 23In this case, an ideal virtual mark for the system is created. Subsequent functions can continue to be executed.
The maximum number of mark failures is set via the Max. number of missed marks (tool) parameter. If no mark is detected within the mark window, an internal counter is incremented. If the number of failed marks reaches the limit set in the Max. number of missed marks (tool) parameter, a corresponding error is output at the error output of the technology application.
0x5041:128
0x5041:128