Mark failure detection

If the output is set via bit 23 in the Status signals parameter, no mark was detected within the configured mark window. 0x5040:110 Bit 23
In this case, an ideal virtual mark for the system is created. Subsequent functions can continue to be executed.
 
The maximum number of mark failures is set via the Max. number of missed marks (tool) parameter. If no mark is detected within the mark window, an internal counter is incremented. If the number of failed marks reaches the limit set in the Max. number of missed marks (tool) parameter, a corresponding error is output at the error output of the technology application. 0x5041:128
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5041:128
Max. number of missed marks (tool)
0 ... [20] ... 4294967295