Position synchronism

Relevant parameters of other functions
Address
Name
Default setting
Setting range
Set position
- (Read only)
Velocity setpoint
- (Read only)
Control signals
0x00000000
0x00000000 ... 0xFFFFFFFF
External base velocity
0.0000
-214748.3648 ... 214748.3647
External position offset
0.0000
-214748.3648 ... 214748.3647
Activate master value correction
0
Stretch factor - numerator
1
1 ... 4294967295
Stretch factor - denominator
1
1 ... 4294967295
Trimming - Reset offset
0
Trimming - Position difference
1.0000
0.0000 ... 214748.3647
Trimming - Velocity
50.0000
-214748.3648 ... 214748.3647
Trimming - Acceleration
100.00
-21474836.48 ... 21474836.47
Trimming - Deceleration
100.00
-21474836.48 ... 21474836.47
Trimming - Jerk
10000.00
-21474836.48 ... 21474836.47
0x5041:031
Clutch mode
Absolute coupling (polynom) [2]
Selection list
Allowed direction
Positive direction [1]
Selection list
Declutch position
0.0000
0.0000 ... 214748.3647
Deceleration of "direct declutching"
5.0000
0.0000 ... 214748.3647
Clutch-in distance
90.0000
0.0000 ... 214748.3647
Declutch distance
90.0000
0.0000 ... 214748.3647
Clutch base velocity
0.0000
-214748.3648 ... 214748.3647
Internal position offset
0.0000
-214748.3648 ... 214748.3647
Corrected set position
- (Read only)
Set position of selected master value
- (Read only)
Set position with offset
- (Read only)
Set velocity with offset
- (Read only)
Set position after measuring system alignment
- (Read only)
Set velocity after measuring system alignment
- (Read only)
Active position offset
- (Read only)
Trimming - Position offset
- (Read only)
Total position offset
- (Read only)
Total velocity offset
- (Read only)
Set base velocity
- (Read only)
Slave set position
- (Read only)
Slave set velocity
- (Read only)