Source of line speed

The line velocity signal can be transferred from different sources in the technology application.
When using the technology application with another i950 series inverter that determines the speed of the machine, the master value is transferred via the system bus. Line velocity source0x5020:020 selection [3]
In the technology application, the line velocity signal is scaled to [mm/s] with 4 decimal places. If the position unit of the master is not the unit [mm], the unit can be adjusted via the numerator-denominator evaluation.
Numerator-denominator evaluation:
–
Evaluation of line velocity - numerator 0x5051:007
 
–
Evaluation of line velocity - denominator 0x5051:008
 
Example:
The speed-determining drive is the master of a machine. The master operates with a rotary dimensional system and a feed constant of [360°/r]. The speed in [°/s] is transmitted to the winder via the system bus. One revolution of the master on the output side conveys the material by 194.7787 [mm] per revolution in the direction of material flow. This distance corresponds to the circumference of the feed roller or the measuring wheel. This results in a factor of 1:1.
Numerator to denominator ratio
–
Evaluation of line velocity - numerator = 194.7787 [mm] (linear feed) 0x5051:007
 
–
Evaluation of line velocity - denominator = 360.0000 [°] (configured feed constant of the master)
0x5051:008
 
If required, the line velocity signal can be negated with a negative value via the Evaluation of line velocity - numerator parameter.
0x5051:007
Fig. 1: Selection of the source for the line velocity
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Interface selection
Fieldbus network [0]
Selection list
Actual velocity
- (Read only)
Line velocity source
External [0]
Selection list
System bus diagnostics: Velocity (input value)
- (Read only)
Evaluation line velocity - numerator
1.0000000000
-2147483648.0000000000 ... 2147483647.0000000000
Evaluation line velocity - denominator
1.0000000000
-2147483648.0000000000 ... 2147483647.0000000000
Actual line velocity
x.xxxx mm/s (Read only)