Commissioning
Preconditions
–
Motor has been commissioned
–
Motor control optimisation has been completed
–
The user is familiar with PC operation via the interface "Internal Control".
This description is based on the Lenze settings of the technology application parameters. Many of the system data required for the parameterisation of the technology applications can be found in the DSD dimensioning report.
Only a subset of the technology application’s functions are relevant to winding drives. Define the functions that will be used for the application to be activated early on. This will make it easier to handle the technology application.
Sample commissioning steps
Fig. 1: Example topology for commissioning
The application data are as follows:
|
Description
|
Calculation value
|
Comment
|
|
Maximum line speed (v)
|
60 m/min => 1000 mm/s
|
In this case, the motor reaches a speed of nmax = 2964 rpm
|
|
Maximum acceleration and deceleration time
|
3 s
|
|
|
Minimum diameter (dmin)
|
76 mm
|
|
|
Maximum diameter (dmax)
|
1250 mm
|
|
|
The standard diameter is not measured and must be specified as a fixed value.
|
||
|
Mass of maximum reel
|
750 kg => J = 1/2 m x r2;
J = 375 kg x 0.625 m2 = 146.48 kg/cm2
|
|
|
Moment of inertia of the motor
|
JMotor = 61 kg/cm2
|
|
|
Moment of inertia of the empty winding shaft
|
JCor = 76 kg/cm2
|
|
|
Ratio between motor and winding shaft
|
i = 12
|
Toothed gearbox
|
|
Potentiometer supplies analog value
|
0 ... 10 V
|
This corresponds to the current dancer position
|
|
The material can be applied alternately from above and below.
|
||
|
The speed-determining drive is an i950 with the "Speed Control" technology application which supplies the master speed in mm/s via the system bus.
|
||
The data on the application can be found in the DSD readout report.
How to commission the technology application:
✓
The system bus is preset as the source for the line speed.
✓
Maximum web tension = 300 [N], which is used as the reference value for scaled tensile force values.
0x5051:015
0x5051:015✓
Run-up value = 150 [N]. 0x5052:010
1.
Enter the gearbox ratio in the kinematics dialogue.
The feed constant has no influence on the movement in this technology application, but only defines the unit of the general speed displays. The parameter Feed constant has the basic setting 360.0000[°].
0x500A:032
0x500A:032a.
In the parameter Gearbox factor - nominator, enter the gearbox ratio = 12.
0x500A:033
0x500A:033b.
In the parameter Gearbox factor - denominator enter the gearbox ratio = 1.
0x500A:034
0x500A:0342.
Select the base settings in the technology application dialogue.
a.
Set the line speed signal to rewinder = 0.
0x5051:011
0x5051:011The winder will now operate as a rewinder.
b.
Set the line speed = 1000.0000 [mm/s].
0x5051:012
0x5051:012The reference speed corresponds to the maximum line speed.
c.
The drive (master) that determines the speed of the machine operates with a rotary measuring system with a feed constant of vk = 360 [°/rev] and sends a speed signal of [°/s] to the winder via the system bus. Every single revolution of the drive conveys the material by s = 194.777 [mm]. The distance s corresponds to the circumference of the feed roll and/or the measuring wheel.
0x5051:007d.
Set the configured feed constant of the master = 360000.
0x5051:008
0x5051:0083.
There is no need to configure any settings other than the standard settings in order to calculate the diameter.
a.
Enter Min. reel diameter = 76.0000 [mm].
0x5051:016
0x5051:016b.
Enter Max. reel diameter = 1250.0000 [mm].
0x5051:017
0x5051:017c.
Enter the Start diameter = 663.0000 [mm].
0x5051:066
0x5051:0664.
Switch to the "Manual line jogging" dialogue.
The winder can only be tested in manual operation. This must be done without any material inside the machine.
a.
To load the start diameter = 663.0000 [mm], set the value = TRUE in bit 22 of the Control signals. 0x5050:010
b.
To move the line in a positive direction, set the value = TRUE in bit 5 of the parameter Control signals. 0x5050:010
c.
To move the line in a negative direction, set the value = TRUE in bit 6 of the parameter Control signals. 0x5050:010
The direction of rotation of the winding shaft is set. If the shaft rotates in the opposite direction, invert the motor mounting position.
The direction of rotation of the winding shaft is set. If the shaft rotates in the opposite direction, invert the motor mounting position.
d.
Adapt the direction of rotation in the parameter Motor mounting direction.
0x500A:035
0x500A:035To do so, refer to the table "Overview of the winding shaft’s direction of rotation depending on the bit settings" at the end of the chapter.
5.
The disturbance compensation for the acceleration and the adaptation of the speed controller gain can be activated via Control signals. 0x5050:010
|
Control Signals
0x5050:010 bit 5
|
Control Signals
0x5950:010 bit 6
|
Control Signals
0x5050:10 bit 28
|
Winding shaft rotating direction
|
|
TRUE
|
FALSE
|
FALSE
|
CCW
|
|
TRUE
|
FALSE
|
TRUE
|
CW
|
|
FALSE
|
TRUE
|
FALSE
|
CW
|
|
FALSE
|
TRUE
|
TRUE
|
CCW
|
Simplified friction compensation
Identify the friction only when the simplified friction function does not adequately represent the actual friction which occurs.
A simplified friction compensation is identified in the DEFAULT settings.
How to set the simplified friction compensation:
1.
Define the starting value.
0x5052:035
For many applications, a suitable starting value is 3 % of the rated motor torque.
0x5051:015
0x5052:035For many applications, a suitable starting value is 3 % of the rated motor torque.
0x5051:0152.
Define the final value.
0x5052:036
For many applications, a suitable final value is 5 % of the rated motor torque.
0x5051:015
0x5052:036For many applications, a suitable final value is 5 % of the rated motor torque.
0x5051:015The simplified friction compensation is now configured.
Execute test run
How to carry out a test run with material:
✓
Material is inserted.
1.
If the diameter is known, load the diameter.
0x5050:010 Bit 22 TRUE
0x5050:010 Bit 22 TRUE2.
If the diameter is unknown, select the starting value 630.0000 mm.
0x5051:066
0x5051:0663.
Set the material feeding.
0x5050:010 Bit 28
0x5050:010 Bit 28a.
Enable tension-controlled (open loop) operation.
0x5050:010 Bit 18 TRUE
0x5050:010 Bit 18 TRUE4.
Enter the tensile force setpoint with 2 decimal positions. Example: 300.00 N.
The run-up starts.
The friction compensation, the acceleration compensation, and the adaptation of the speed controller gain can be activated via the control word.
0x5050:010
0x5050:010The current line speed signal is displayed in the parameter Actual line velocity
0x5051:009
0x5051:009The reference value for the scaled line speed signals is defined in [%] in the parameter Line velocity reference.
0x5051:012
0x5051:012Additional optimisation steps
How to optimise the commissioning
Preconditions
✓
The commissioning is complete.
1.
Optimise the adaptation of the speed controller gain, e.g. by selecting a different mode or a multiplicative adaptation.
Adapting the speed controller gain
Adapting the speed controller gain2.
Optimise acceleration compensation, e.g. adapt it to the current material density or material width.
Acceleration compensation
Acceleration compensation 3.
Optimise friction compensation, e.g. when the gearbox oil temperature varies.
0x5052:120
0x5052:1204.
Optimise the tensile force setting, e.g. when the tensile force starts up too jerkily.
0x5052:120
0x5052:120The optimisation process is now complete.
|
Name
|
Value
|
Unit
|
Parameter
|
|
Line velocity reference
|
60
|
m/min
|
|
|
1000
|
mm/s
|
||
|
Speed
|
2964
|
r/m
|
DEFAULT
|
|
Acceleration time
|
3
|
s
|
DEFAULT
|
|
Deceleration time
|
3
|
s
|
DEFAULT
|
|
Min. reel diameter
|
76
|
mm
|
|
|
Max. reel diameter
|
1250
|
mm
|
|
|
Start diameter
|
663.0000
|
mm
|
|
|
Load the starting diameter
|
-
|
mm
|
0x5050:010 Bit 22
|
|
Max. Mass
|
750
|
kg
|
-
|
|
Constant moment of inertia
|
61
|
kg*cm2
|
|
|
Max. moment of inertia
|
76
|
kg*cm2
|
|
|
Gearbox factor - nominator
|
12
|
i
|
|
|
Gearbox factor - denominator
|
1
|
i
|
|
|
Maximum web tension at min. diameter
|
300
|
N
|
0x5050:003
|
|
Max. Web tension at max. diameter
|
225
|
N
|
-
|
|
Motor mounting direction
|
-
|
-
|
|
|
Set tensile force ramp
|
150
|
N
|
|
|
Test winder in positive direction
|
-
|
-
|
0x5050:010 Bit 5 TRUE
|
|
Test winder in negative direction
|
-
|
-
|
0x5050:010 Bit 6 TRUE
|