Commissioning

Preconditions
–
Motor has been commissioned
 
–
Motor control optimisation has been completed
 
–
The user is familiar with PC operation via the interface "Internal Control".
 
This description is based on the Lenze settings of the technology application parameters. Many of the system data required for the parameterisation of the technology applications can be found in the DSD dimensioning report.
 
Only a subset of the technology application’s functions are relevant to winding drives. Define the functions that will be used for the application to be activated early on. This will make it easier to handle the technology application.
 
Sample commissioning steps
Fig. 1: Example topology for commissioning
 
The application data are as follows:
Description
Calculation value
Comment
Maximum line speed (v)
60 m/min => 1000 mm/s
In this case, the motor reaches a speed of nmax = 2964 rpm
Maximum acceleration and deceleration time
3 s
Minimum diameter (dmin)
76 mm
Maximum diameter (dmax)
1250 mm
The standard diameter is not measured and must be specified as a fixed value.
Mass of maximum reel
750 kg => J = 1/2 m x r2;
J = 375 kg x 0.625 m2 = 146.48 kg/cm2
Moment of inertia of the motor
JMotor = 61 kg/cm2
Moment of inertia of the empty winding shaft
JCor = 76 kg/cm2
Ratio between motor and winding shaft
i = 12
Toothed gearbox
Potentiometer supplies analog value
0 ... 10 V
This corresponds to the current dancer position
The material can be applied alternately from above and below.
The speed-determining drive is an i950 with the "Speed Control" technology application which supplies the master speed in mm/s via the system bus.
The data on the application can be found in the DSD readout report.
 
 
How to commission the technology application:
✓
The system bus is preset as the source for the line speed.
 
✓
Maximum web tension = 300 [N], which is used as the reference value for scaled tensile force values. 0x5051:015
 
✓
Run-up value = 150 [N]. 0x5052:010
 
1.
Enter the gearbox ratio in the kinematics dialogue.
The feed constant has no influence on the movement in this technology application, but only defines the unit of the general speed displays. The parameter Feed constant has the basic setting 360.0000[°]. 0x500A:032
 
a.
In the parameter Gearbox factor - nominator, enter the gearbox ratio  = 12. 0x500A:033
 
b.
In the parameter Gearbox factor - denominator enter the gearbox ratio = 1. 0x500A:034
 
2.
Select the base settings in the technology application dialogue.
 
a.
Set the line speed signal to rewinder = 0. 0x5051:011
The winder will now operate as a rewinder.
 
b.
Set the line speed = 1000.0000 [mm/s]. 0x5051:012
The reference speed corresponds to the maximum line speed.
 
c.
The drive (master) that determines the speed of the machine operates with a rotary measuring system with a feed constant of vk = 360 [°/rev] and sends a speed signal of [°/s] to the winder via the system bus. Every single revolution of the drive conveys the material by s = 194.777 [mm]. The distance s corresponds to the circumference of the feed roll and/or the measuring wheel.
 
Set the linear feed = 2387610. 0x5051:007
 
d.
Set the configured feed constant of the master = 360000. 0x5051:008
 
3.
There is no need to configure any settings other than the standard settings in order to calculate the diameter.
 
Switch to the "Calculate diameter" dialogue.
 
a.
Enter Min. reel diameter = 76.0000 [mm]. 0x5051:016
 
b.
Enter Max. reel diameter = 1250.0000 [mm]. 0x5051:017
 
c.
Enter the Start diameter = 663.0000 [mm]. 0x5051:066
 
4.
Switch to the "Manual line jogging" dialogue.
The winder can only be tested in manual operation. This must be done without any material inside the machine.
 
 
a.
To load the start diameter = 663.0000 [mm], set the value = TRUE in bit 22 of the Control signals. 0x5050:010
 
b.
To move the line in a positive direction, set the value = TRUE in bit 5 of the parameter Control signals. 0x5050:010
 
c.
To move the line in a negative direction, set the value = TRUE in bit 6 of the parameter Control signals. 0x5050:010
The direction of rotation of the winding shaft is set. If the shaft rotates in the opposite direction, invert the motor mounting position.
 
d.
Adapt the direction of rotation in the parameter Motor mounting direction. 0x500A:035
To do so, refer to the table "Overview of the winding shaft’s direction of rotation depending on the bit settings" at the end of the chapter.
 
 
5.
The disturbance compensation for the acceleration and the adaptation of the speed controller gain can be activated via Control signals. 0x5050:010
 
Overview of the direction of rotation of the winding shaft depending on the bit settings
Control Signals
0x5050:010 bit 5
Control Signals
0x5950:010 bit 6
Control Signals
0x5050:10 bit 28
Winding shaft rotating direction
TRUE
FALSE
FALSE
CCW
TRUE
FALSE
TRUE
CW
FALSE
TRUE
FALSE
CW
FALSE
TRUE
TRUE
CCW
 
 
Simplified friction compensation
Identify the friction only when the simplified friction function does not adequately represent the actual friction which occurs.
A simplified friction compensation is identified in the DEFAULT settings.
 
How to set the simplified friction compensation:
1.
Define the starting value. 0x5052:035
For many applications, a suitable starting value is 3 % of the rated motor torque. 0x5051:015
 
2.
Define the final value. 0x5052:036
For many applications, a suitable final value is 5 % of the rated motor torque. 0x5051:015
The simplified friction compensation is now configured.
 
 
Execute test run
How to carry out a test run with material:
✓
Material is inserted.
 
1.
If the diameter is known, load the diameter. 0x5050:010 Bit 22 TRUE
 
2.
If the diameter is unknown, select the starting value 630.0000 mm. 0x5051:066
 
3.
Set the material feeding. 0x5050:010 Bit 28
 
a.
Enable tension-controlled (open loop) operation. 0x5050:010 Bit 18 TRUE
 
4.
Enter the tensile force setpoint with 2 decimal positions. Example: 300.00 N.
 
The run-up starts.
The friction compensation, the acceleration compensation, and the adaptation of the speed controller gain can be activated via the control word. 0x5050:010
The current line speed signal is displayed in the parameter Actual line velocity 0x5051:009
The reference value for the scaled line speed signals is defined in [%] in the parameter Line velocity reference. 0x5051:012
 
Additional optimisation steps
How to optimise the commissioning
Preconditions
✓
The commissioning is complete.
 
1.
Optimise the adaptation of the speed controller gain, e.g. by selecting a different mode or a multiplicative adaptation. Adapting the speed controller gain
 
2.
Optimise acceleration compensation, e.g. adapt it to the current material density or material width. Acceleration compensation
 
3.
Optimise friction compensation, e.g. when the gearbox oil temperature varies. 0x5052:120
 
4.
Optimise the tensile force setting, e.g. when the tensile force starts up too jerkily. 0x5052:120
 
The optimisation process is now complete.
 
Basic data
Name
Value
Unit
Parameter
Line velocity reference
60
m/min
1000
mm/s
Speed
2964
r/m
DEFAULT
Acceleration time
3
s
DEFAULT
Deceleration time
3
s
DEFAULT
Min. reel diameter
76
mm
Max. reel diameter
1250
mm
Start diameter
663.0000
mm
Load the starting diameter
-
mm
0x5050:010 Bit 22
Max. Mass
750
kg
-
Constant moment of inertia
61
kg*cm2
Max. moment of inertia
76
kg*cm2
Gearbox factor - nominator
12
i
Gearbox factor - denominator
1
i
Maximum web tension at min. diameter
300
N
0x5050:003
Max. Web tension at max. diameter
225
N
-
Motor mounting direction
-
-
Set tensile force ramp
150
N
Test winder in positive direction
-
-
0x5050:010 Bit 5 TRUE
Test winder in negative direction
-
-
0x5050:010 Bit 6 TRUE