Synchronisation to line speedSynchronisation to line speed

In the case of commissioning without material, a simple speed follower function is used. This speed follower function checks whether the axis follows the master value at the expected speed, including when the diameter changes.
The expected speed is calculated as follows:
Calculation of the speed
1/min
1/min
Revolutions per minute
v
mm/s
Line velocity
d
mm
Diameter
 
As test equipment, a manual tachometer is placed on the outer circumference of the winder. This manual tachometer displays the circumferential speed. The circumferential speed is compared with the speed shown in the parameter Actual line velocity. 0x5051:009
The parameters Acceleration to synchronize to line velocity and Deceleration to synchronize to line velocity determine the acceleration and deceleration behaviour.
Parameters for the acceleration and deceleration behaviour:
–
Acceleration to synchronize to line velocity 0x5051:020
 
–
Deceleration to synchronize to line velocity 0x5051:021
 
The Actual diameter must correspond to the actual diameter when the speed follower function is requested. 0x5051:096
When the value stored in the parameter Actual diameter does not correspond to the actual diameter, the winding shaft may be rotated at an unexpected speed. 0x5051:096
 
The synchronisation of the winder axis with the line speed is performed with bit 16 = TRUE of the parameter Control signals. 0x5050:010
Bit 16 = TRUE of the parameter Status signals indicates that the synchronisation is complete. 0x5050:110
The circumferential speed now corresponds to the line speed.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5051:009
Actual line velocity
–
Read only: x.xxxx mm/s
 
The parameter is resolved with 4 decimal positions. The parameter has the unit [mm/s].
0x5051:020
Acceleration to synchronize to line velocity
1.00 ... [50.00] ... 21474836.47 mm/s²
0x5051:021
Deceleration to synchronize to line velocity
1.00 ... [50.00] ... 21474836.47 mm/s²
0x5051:096
Actual diameter
–
Read only: x.xxxx mm
 
The parameter is resolved with 4 decimal positions. The parameter has the unit [mm].