Control settings
General variables such as starting values, reference variables, and signal sources must be defined before the control system of the technology application is configured.
The digits 1 ... 5 designate the recommended sequence during commissioning.
Fig. 1: Sequence of commissioning steps
Settings in
"
EASY Starter"
:–
Settings tab
–
Technology application parameter dialogue for
–
Application selection
0x4000
0x4000Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
Interface selection
|
Fieldbus network [0]
|
Selection list
|
|
|
Application quick stop source
|
FALSE [0]
|
Selection list
|
|
|
Source of fault reset
|
FALSE [0]
|
Selection list
|
|
|
Line velocity source
|
External [0]
|
Selection list
|
|
|
Source of digital output 1
|
Ready to switch on [0]
|
Selection list
|
|
|
Display value 1
|
Actual tension [9]
|
Selection list
|
|
|
Display value 2
|
Master speed limit [8]
|
Selection list
|
|
|
Evaluation line velocity - numerator
|
1.0000000000
|
-2147483648.0000000000 ... 2147483647.0000000000
|
|
|
Evaluation line velocity - denominator
|
1.0000000000
|
-2147483648.0000000000 ... 2147483647.0000000000
|
|
|
Winding direction with line velocity > 0
|
0
|
|
|
|
Line velocity reference
|
1000.0000 mm/s
|
0.0000 ... 214748.3647 mm/s
|
|
|
Tensile force reference value
|
2.00 N
|
0.00 ... 21474836.47 N
|
|
|
Min. reel diameter
|
50.0000 mm
|
1.0000 ... 10000.0000 mm
|
|
|
Max. reel diameter
|
180.0000 mm
|
1.0000 ... 10000.0000 mm
|