Adapting the speed controller gain

If we consider the motor and the reel as a rigid one-mass system, the gain of the speed controller is directly proportional to the moment of inertia.
During the winding process, the moment of inertia changes. Gain adjustment is required to match the gain of the speed controller to the moment of inertia.
According to the selected method, an adjustment factor is formed depending on the current diameter or the moment of inertia. The adjustment factor is used to multiplicatively evaluate the gain factor for the speed controller. The set amplification only takes effect at maximum diameter or maximum mass moment of inertia. The gain in the motor control is evaluated in the parameter Speed controller settings: Gain. Only when the factor is 100 [%] is the value from the parameter Speed controller settings: Gain takes effect. 0x2900:001
Fig. 1: Dialog overview "Speed control gain"
 
The speed controller is not active in open and closed-loop tension-controlled operation. The adapted speed controller gain offers the option of working with adapted speed controller gain in the operating mode Manual inching or in the case of the Quick stop function.
 
The parameter Speed control adaption min. value defines the smallest evaluation factor. 0x5051:031
 
Setting the bit 29 = TRUE in parameter Control word enables the speed controller adjustment.
If reels are used that exhibit different moments of inertia despite having the same diameter due to e.g. different material densities and material widths, this must be taken into account when adjusting the speed controller. This is done by using the multiplicative evaluation of the current adjustment factor: Speed controller gain adaption. 0x5051:029
In this case, a value of 100.00 [%] corresponds to an evaluation of 1 at the maximum moment of inertia.
The adjustment factor is output in the parameter Speed controller actual gain. 0x5051:032
Fig. 2: Example: Characteristics for the adjustment of the gain depending on the selected mode
1
Mode: Inertia  
 
2
Mode: DiamToSquare  
 
3
Mode: Diam 
 
 
 
Parameter
Adjustment factor
DiamToSquare
dact2/dmax2
Diam
dact/dmax
Inertia
Jact/Jmax
Mode adaptation to speed controller
Parameter index and selection
Define moment of inertia
Application
No
–
Low acceleration feedforward control
 
–
Suitable for a wide range of mechanics
 
–
Suitable for various materials
 
No
–
An acceleration feedforward control that is lower than selection [1]
 
–
Softer response
 
Yes
–
Exact acceleration feedforward control
 
–
Suitable for rigid mechanics
 
–
Suitable for rigid materials
 
The moments of inertia entered under Constant moment of inertia and Max. moment of inertia for the parameter Speed controller adaption mode must be plausible.
–
Speed controller adaption mode 0x5051:030
 
–
Constant moment of inertia 0x5051:111
 
–
Max. moment of inertia 0x5051:112
 
 
The effective adjustment factor is displayed in the parameter Speed controller actual gain. 0x5051:032
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5051:029
Speed controller gain adaption
0.00 ... [100.00] ... 100.00 %
0x5051:030
Speed controller adaption mode
0
Vp adaption = d²
1
Vp adaption = d [%]
2
Vp adaption = act. J [%]
0x5051:031
Speed control adaption min. value
0.00 ... [20.00] ... 100.00 %
0x5051:032
Speed controller actual gain
–
Read only: x.xx %
 
0x5051:096
Actual diameter
–
Read only: x.xxxx mm
 
The parameter is resolved with 4 decimal positions. The parameter has the unit [mm].
0x5051:110
Actual moment of inertia
–
Read only
 
The parameter is only shown.
0x5051:111
Constant moment of inertia
1.0000000000 ... [1.0000000000] ... 2147483647.0000000000
The parameter has the unit [kgcm2].
0x5051:112
Max. moment of inertia
1.0000000000 ... [10.0000000000] ... 2147483647.0000000000