Signal flow
Fig. 1: Basic signal flow
Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
Diagnostics of analog input 1: Scaled percent value
|
x.xx % (Read only)
|
||
|
Actual velocity
|
- (Read only)
|
||
|
Line velocity source
|
External [0]
|
Selection list
|
|
|
Actual tension source
|
Analog input 1 [2]
|
Selection list
|
|
|
System bus diagnostics: Velocity (input value)
|
- (Read only)
|
||
|
Set velocity
|
0.0000 mm/s
|
-214748.3648 ... 214748.3647 mm/s
|
|
|
Set tension
|
0.00 N
|
-21474836.48 ... 21474836.47 N
|
|
|
Actual tension
|
0.00 N
|
-21474836.48 ... 21474836.47 N
|
|
|
Evaluation line velocity - numerator
|
1.0000000000
|
-2147483648.0000000000 ... 2147483647.0000000000
|
|
|
Evaluation line velocity - denominator
|
1.0000000000
|
-2147483648.0000000000 ... 2147483647.0000000000
|
|
|
Actual line velocity
|
x.xxxx mm/s (Read only)
|
||
|
Line velocity reference
|
1000.0000 mm/s
|
0.0000 ... 214748.3647 mm/s
|
|
|
Line velocity offset
|
10.00 %
|
0.00 ... 100.00 %
|
|
|
Filter time actual reel speed
|
0.010 s
|
0.000 ... 10.000 s
|
|
|
Speed controller gain adaption
|
100.00 %
|
0.00 ... 100.00 %
|
|
|
Speed controller adaption mode
|
Vp adaption = d² [0]
|
Selection list
|
|
|
Speed control adaption min. value
|
20.00 %
|
0.00 ... 100.00 %
|
|
|
Speed controller actual gain
|
x.xx % (Read only)
|
||
|
Upper speed limit
|
x.xx rev/s (Read only)
|
||
|
Lower speed limit
|
x.xx rev/s (Read only)
|
||
|
Winder set torque
|
x.xxxx Nm (Read only)
|
||
|
Winder speed
|
x.xx rev/s (Read only)
|
||
|
Actual diameter
|
x.xxxx mm (Read only)
|
||
|
Actual moment of inertia
|
- (Read only)
|
||
|
Acceleration compensation set torque
|
x.xxxx Nm (Read only)
|
||
|
External set tension
|
x.xx N (Read only)
|
||
|
Tensile force characteristic - actual output value
|
x.xx N (Read only)
|
||
|
Set tension source
|
External [0]
|
Selection list
|
|
|
Set tension
|
4.00 N
|
0.00 ... 21474836.47 N
|
|
|
Tension control - set tensile force
|
x.xx N (Read only)
|
||
|
Adaption factor of actual tensile force
|
100.00 %
|
1.00 ... 100.00 %
|
|
|
Actual tensile force offset
|
0.00 N
|
0.00 ... 21474836.47 N
|
|
|
Filter time actual tensile force
|
0.005 s
|
0.000 ... 10.000 s
|
|
|
Filtered actual tensile force
|
x.xx N (Read only)
|
||
|
Tension control - actual output
|
x.xx N (Read only)
|
||
|
Friction compensation - torque
|