Speed limitation

In open and closed-loop tension-controlled operation with material, the winder speed is determined by the circumferential speed and the rotational speed. A speed limitation is triggered in the case of a web break and when there is an overcompensation of a disturbance. The speed limitation prevents the reel from accelerating in direction nmax .
 
The percentage lead with respect to the line velocity is defined with the parameter Offset line velocity. 0x5051:014
The standard setting is 10 [%].
The set speed limitations can be read in the following parameters:
–
Upper speed limit value 0x5051:034
 
–
Lower speed limit value 0x5051:035
 
If the speed limitation has been activated, the status word 26 = TRUE.
Fig. 1: Dialog overview "Monitoring settings - Speed limitation"
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5051:009
Actual line velocity
–
Read only: x.xxxx mm/s
 
The parameter is resolved with 4 decimal positions. The parameter has the unit [mm/s].
0x5051:012
Line velocity reference
0.0000 ... [1000.0000] ... 214748.3647 mm/s
0x5051:014
Line velocity offset
0.00 ... [10.00] ... 100.00 %
0x5051:034
Upper speed limit
–
Read only: x.xx rev/s
 
0x5051:035
Lower speed limit
–
Read only: x.xx rev/s
 
0x5051:037
Winder speed
–
Read only: x.xx rev/s