Diameter hold
If the line velocity does not correspond to the circumferential speed, the diameter cannot be calculated from the line speed and the motor speed. In this case, the calculated diameter moves in direction dmax or dmin, depending on the winding direction. Bit 21 is set when the diameter is being maintained, but not when the line speed signal does not correspond to the circumferential speed. The bit is set in parameter Status signals = TRUE. 0x5050:110 Bit 21
Bit 21 is set to TRUE in the following cases:
–
Actual line velocity in [mm/s] < Min. line velocity in [mm/s].
–
In the states:
See parameter Technology application state.
0x5051:001
–
STOP
–
ERROR
–
READY
–
JOGGING
–
SYNCLINEVEL
0x5051:001For the user-side maintenance of the diameter, control bit 21 of parameter Control signals has to be set to TRUE. 0x5050:010 Bit 21
Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
Actual line velocity
|
x.xxxx mm/s (Read only)
|
||
|
Min. line velocity
|
1.0000 mm/s
|
-214748.3648 ... 214748.3647 mm/s
|
|
|
Winder speed
|
x.xx rev/s (Read only)
|
||