Status signals

Parameter
Address
Name / setting range / [default setting]
Information
0x5050:110
Status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  0
Ready for operation
Axis ready for switch-on.
Bit  1
Homing active
Homing is active.
Bit  2
Operation enabled
Axis is enabled.
Bit  3
Fault
An error is active.
Bit  4
Homing done
Homing was completed successfully.
Bit  5
Application quick stop active
Quick stop was triggered.
Bit  6
Manual jog active
Manual operation is active.
Bit  7
Warning
A warning is active.
Bit  8
Halt active
A stop was triggered in the application.
Bit  9
Motor control in limitation
The motor control is in limitation.
Bit  10
Set position reached
Actual position = setpoint position
Bit  11
Abort busy
The active movement is canceled.
Bit  12
Standstill
Standstill reached.
Bit  13
Direction of rotation inverted
Direction of rotation is inverted.
Bit  14
Brake opened
The holding brake is open.
Bit  15
STO active
Safe Torque Off is active.
Bit  16
Winder syncronized to line
The winder is synchronous with the line velocity.
Bit  17
Unwinding operation
The unwind mode is active.
Bit  18
Tension control active
Tension-controlled operation is active.
Bit  19
Status bit 19 (reserved)
Bit without function
Bit  20
Status bit 20 (reserved)
Bit  21
Diameter hold active
The diameter is being maintained.
Bit  22
Max. diameter reached
The maximum diameter has been reached.
Bit  23
Min. diameter reached
The minimum diameter has been reached.
Bit  24
Web break
A web break has been detected.
Bit  25
Status bit 25 (reserved)
Bit without function
Bit  26
Status bit 26 (reserved)
Bit  27
Status bit 27 (reserved)
Bit  28
Velocity limit reached
Speed limitation reached.
Bit  29
Ready for motion
The axis is ready to move.
Bit  30
Identification active
An identification is active.
Bit  31
Status bit 31 (reserved)
Bit without function
0x5050:111
Status signals limiter
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Extended Safety - status of the monitoring functions
Bit  0
STO active
Safe torque off (STO) active.
The axis is safely switched to torqueless operation.
Bit  1
SS1 active
Safe stop 1 (SS1) active.
Subsequently, the drive is torqueless (STO).
Bit  2
SS2 active
Safe stop 2 (SS2) active.
The drive then changes to the safe operational stop (SOS).
Bit  3
SOS active
Safe operational stop (SOS) active.
The reached position is actively held.
Bit  4
SLS1 active
Safely limited speed (SLS1) active.
The travel profile changes according to the parameters set for it.
Bit  5
SLS2 active
Safely limited speed (SLS2) active.
The travel profile changes according to the parameters set for it.
Bit  6
SLS3 active
Safely limited speed (SLS3) active.
The travel profile changes according to the parameters set for it.
Bit  7
SLS4 active
Safely limited speed (SLS4) active.
The travel profile changes according to the parameters set for it.
Bit  8
SDpos active
Safe direction (SDI) active.
Only the positive direction is allowed.
Bit  9
SDneg active
Safe direction (SDI) active.
Only the negative direction is allowed.
Bit  10
SLI active
Safely limited increment (SLI) active.
A maximum permissible change in position is monitored.
Bit  11
SSE active
Safe stop emergency (SSE) active.
Bit  12
ES active
Enable switch (ES) active.
The stop functions in special mode are overridden.
Bit  13
OMS active
Operation mode selector (OMS) active.
Special operation is active.
0x5050:112
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
Display of the actual velocity
0x5050:113
Actual position
-214748.3648 ... [0.0000] ... 214748.3647
Display of the actual position
0x5050:114
Error code
0 ... [0] ... 4294967295
Display of the current error number.
0x5050:115
Actual diameter
-214748.3648 ... [0.0000] ... 214748.3647 mm
Display of the actual torque
0x5050:116
Display value 1
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 1"
Selection: 0x5050:006
0x5050:117
Display value 2
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 2"
Selection: 0x5050:007
0x5051:001
Technology application state
–
Read only
 
-1
Disabled
0
Void
1
Initialisation
2
Ready for operation
3
Homing
4
MoveVel
5
MoveAbs
6
MoveRel
7
External
8
Error
9
Resume positioning
10
Manual jog
30
Acc_Dec_Sync
31
Clutch closed
36
MoveToTargetPos
38
Positioning
51
Basevelocity
52
Acc_Dec
60
ContMotion
65
Manual jog with constant line velocity
70
Synchronization
80
Moment of inertia identification
81
Diameter identification
90
Friction identification
100
Dancer control
110
Tension control
121
Operating mode CSV
122
Operating mode CST
123
Operating mode CSP
130
CyclicMotion
1000
System fault