Web break monitoring
Only activate web break monitoring when the calculated diameter corresponds to the real diameter!
In the event of a web break:
–
The calculated diameter changes in the opposite direction to that of the winding direction.
–
The circumferential speed no longer corresponds to the line speed signal.
When the parameter Web break detection window size = 0 or = 2, a diameter change in the opposite direction to that of the winding direction is only still permissible within the window configured in the parameter Web break detection window size.
0x5051:072
0x5051:072How to activate web break monitoring:
1.
Set bit 24 of parameter Control words = TRUE.
0x5050:010
0x5050:010The last valid diameter value is maintained as soon as a web break is identified.
|
Function
|
Parameter index
|
Bit
|
Bit status
|
|
Web break monitoring detected
|
0x5050:110
|
24
|
TRUE
|
|
Diagnose winding direction
|
0x5050:110
|
17
|
TRUE
|
Loading a start diameter that significantly deviates from the real diameter in the direction opposite the winding direction can unintentionally trigger the monitoring function. This can happen, for example, when a standard diameter of 50 [%] is loaded at the rewinder and the real diameter is only 45 [%]. In such a case, the activated web break monitoring function will prevent the diameter value from changing to the real 45 [%].