Single-axis kinematic: Status (subindex 4 )
|
State of the single-axis kinematic
|
|||||||||||||
|
Selection list (read only; initialisation printed in bold) |
Info |
||||||||||||
|
0 |
Unknown |
Unknown |
|||||||||||
|
1 |
ErrorStop |
Error |
|||||||||||
|
2 |
Disabled |
Axes are not coupled |
|||||||||||
|
3 |
Standby |
Axes are coupled. Regulator is off |
|||||||||||
|
5 |
SyncIn |
Alignment is active |
|||||||||||
|
6 |
Synchronized |
Motion can be executed |
|||||||||||
|
8 |
Homing |
Homing is active |
|||||||||||
|
11 |
Maintanance |
Service mode is active / Axes are decoupled |
|||||||||||
|
|
UNSIGNED_16 |
||||||||||||