Information on the network

The following parameters show information on the network.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x1C0A:001
DLL_CNCollision_REC: CumulativeCnt_U32
0 ... [0] ... 4294967295
–
From version 05.00
 
Display of the number of "collision" errors detected by the controlled node.
–
The counter content is increased each time by 1 if the controlled node has detected a "collision" error.
 
0x1C0B:001
DLL_CNLossSoC_REC: CumulativeCnt_U32
0 ... [0] ... 4294967295
–
From version 05.00
 
Display of the number of SoC losses detected by the controlled node.
–
The counter content is increased each time by 1 if the controlled node has detected an SoC loss.
 
0x1C0B:002
DLL_CNLossSoC_REC: ThresholdCnt_U32
–
Read only
 
–
From version 05.00
 
Display of the network quality with regard to SoC losses.
–
The counter content is increased each time by 8 if the controlled node has detected an SoC loss and decreased by 1 at every error-free cycle.
 
0x1C0B:003
DLL_CNLossSoC_REC: Threshold_U32
0 ... [0] ... 4294967295
–
From version 05.00
 
Error threshold for monitoring SoC losses.
–
If the counter content displayed in 0x1C0B:002 reaches the set threshold, the error response selected in 0x2859:011 is effected.
 
–
If the setting is "0", this monitoring is not active.
 
0x1C0F:001
DLL_CNCRCError_REC: CumulativeCnt_U32
0 ... [0] ... 4294967295
–
From version 05.00
 
Display of the number of CRC errors detected by the controlled node.
–
The counter content is increased each time by 1 if the controlled node has detected a "CRC" error.
 
0x1C0F:002
DLL_CNCRCError_REC: ThresholdCnt_U32
–
Read only
 
–
From version 05.00
 
Display of the network quality with regard to CRC errors.
–
The counter content is increased each time by 8 if the controlled node has detected a CRC error and decreased by 1 at every error-free cycle.
 
0x1C0F:003
DLL_CNCRCError_REC: Threshold_U32
0 ... [0] ... 4294967295
–
From version 05.00
 
Error threshold for monitoring CRC errors.
–
If the counter content displayed in 0x1C0F:002 reaches the set threshold, the error response selected in 0x2859:010 is effected.
 
–
If the setting is "0", this monitoring is not active.
 
0x1C10
DLL_CNLossOfLinkCum_U32
0 ... [0] ... 4294967295
–
From version 05.00
 
Display of the number of connection losses detected by the controlled node.
–
The counter content is increased each time by 1 if the controlled node has detected a connection loss.
 
–
A connection loss may occur if the connection is interrupted, for instance due to a cable break/unplugging the network cable or a defect hub/switch in the POWERLINK network.
 
0x1F82
NMT_FeatureFlags_U32
–
Read only
 
–
From version 05.00
 
Bit coded display of the POWERLINK functions implemented by the POWERLINK nodes.
The single bits have the following meaning:
–
Bit 0 = 1 = node with this ID exists.
 
–
Bit 1 = 1 = node with this ID is a controlled node.
 
–
Bit 2 = 1 = If a booting controlled node is detected, this is reported to the application and the controlled node is started.
 
–
Bit 3 = 1 = controlled node is mandatory.
 
–
Bit 4 = 1 = managing node must not send any reset commands.
 
–
Bit 5 = 1 = software version verification of the controlled node required.
 
–
Bit 6 = 1 = automatic software update of the application permitted.
 
–
Bit 7 = reserved (no function)
 
–
Bit 8 = 1 = controlled node is addressed asynchronously.
 
–
Bit 9 = 1 = controlled node is addressed in a multiplexed way.
 
–
Bit 10 = 1 = device is router (type 1)
 
–
Bit 11 = 1 = device is router (type 2)
 
–
Bit 12 = 1 = managing node sends PRes frames.
 
–
Bit 13 ... 30 = reserved (no function)
 
–
Bit 31 = 1 = bits 0 ... 30 are enabled.
 
0x1F83
NMT_EPLVers_U8
–
Read only
 
–
From version 05.00
 
Display of the POWERLINK version.
0x1F8C
NMT_CurrState_U8
–
Read only
 
–
From version 05.00
 
Display of the current NMT state of the POWERLINK node (according to the Ethernet POWERLINK specification).
0x1F93:001
NMT_EPLNodeID_REC: NodeID_U8
–
Read only
 
–
From version 05.00
 
Display of the currently valid node address (node ID).
0x1F93:002
NMT_EPLNodeID_REC: NodeIDByHW_BOOL
–
Read only
 
–
From version 05.00
 
Display whether the node address (node ID) has been set via rotary encoder switch or via software.
0x1F98:001
NMT_CycleTiming_REC: IsochrTxMaxPayload_ U16
–
Read only
 
–
From version 05.00
 
Display of the size of the isochronous transmit memory.
0x1F98:002
NMT_CycleTiming_REC: IsochrRxMaxPayload_ U16
–
Read only
 
–
From version 05.00
 
Display of the size of the isochronous receive memory.
0x1F98:003
NMT_CycleTiming_REC: PResMaxLatency_U32
–
Read only: x ns
 
–
From version 05.00
 
Display of the isochronous response delay.
0x23C2:001
Active POWERLINK settings: IP address
–
Read only
 
–
From version 05.00
 
Display of the active IP address.
0x23C2:002
Active POWERLINK settings: Subnet
–
Read only
 
–
From version 05.00
 
Display of the active subnet mask.
0x23C2:003
Active POWERLINK settings: Gateway
–
Read only
 
–
From version 05.00
 
Display of the IP address of the router that connects the POWERLINK segment to the higher-level network.
0x23C2:004
Active POWERLINK settings: Node ID
–
Read only
 
–
From version 05.00
 
Display of the active node address (node ID) in the network.
0x23C2:005
Active POWERLINK settings: MAC Address
–
Read only
 
–
From version 05.00
 
Display of the active MAC address.
0x23C2:007
Active POWERLINK settings: Tx length
–
Read only
 
–
From version 05.00
 
Display of the length of the transmitted cyclic data in bytes.
0x23C2:008
Active POWERLINK settings: Rx length
–
Read only
 
–
From version 05.00
 
Display of the length of the received cyclic data in bytes.
0x23C3
POWERLINK switch position
–
Read only
 
–
From version 05.00
 
Display of the rotary encoder switch setting at the last mains power-on.
0x23C8:001
POWERLINK status: Network management
–
Read only
 
–
From version 05.00
 
Display of the current bus status.
9
NMT_CS_INITIALISATION
28
NMT_CS_NOT_ACTIVE
29
NMT_CS_PRE_OPERATIONAL_1
30
NMT_CS_BASIC_ETHERNET
77
NMT_CS_STOPPED
93
NMT_CS_PRE_OPERATIONAL_2
109
NMT_CS_READY_TO_OPERATE
253
NMT_CS_OPERATIONAL
0x23C9:001
POWERLINK error: Activation
–
Read only
 
–
From version 05.00
 
Bit coded display of the bus error state reported by the LED "BE" (Bus Error).
–
Bit 0 = 0 (0x0000) = no bus error
 
–
Bit 0 = 1 (0x0001) = active bus error
 
0
Disabled
1
Activated