Digital inputs and outputs

The following parameters serve to diagnose the digital inputs and outputs of the inverter.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x60FD
Digital input status
–
Read only
 
Bit coded display of the current status of the digital inputs
Bit 0
Reserved
-
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Digital input 1
0 = LOW level, 1 = HIGH level.
Bit 17
Digital input 2
Bit 18
Digital input 3
Bit 19
Digital input 4
Bit 20
Digital input 5
Bit 21
Digital input 6
Bit 22
Digital input 7
Bit 23
Digital input 8
Bit 24
Reserved
-
Bit 25
Internal interconnection of digital inputs
0 = digital inputs are internally set to HIGH (NPN) level via pull-up resistors.
1 = digital inputs are internally set to LOW (PNP) level via pull-down resistors.
Bit 26
Reserved
-
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31