Analog inputs and outputs

Parameter
Address
Name / setting range / [default setting]
Information
0x2DA4:001
Diagnostics of analog input 1: Value in percent
–
Read only: x.x %
 
Display of the current input value at X3/AI1 scaled as value in percent.
–
100 % = 10 V or 20 mA or 5 V
 
0x2DA4:002
Diagnostics of analog input 1: Frequency value
–
Read only: x.x Hz
 
Display of the current input value at X3/AI1 scaled as a frequency value.
–
The standard setpoint source for operating mode 0x6060 = "MS: Velocity mode [-2]" is selected in 0x2860:001.
 
0x2DA4:003
Diagnostics of analog input 1: Process controller value
–
Read only: x.xx PID unit
 
Display of the current input value at X3/AI1 scaled as a process controller value.
–
The standard setpoint source for the reference value of PID control is selected in 0x2860:002.
 
0x2DA4:004
Diagnostics of analog input 1: Torque value
–
Read only: x.x %
 
Display of the current input value at X3/AI1 scaled as a percentage torque value.
–
100 % = permissible maximum torque 0x6072
 
–
The standard setpoint source for operating mode 0x6060 = "MS: Torque mode [-1]" is selected in 0x2860:003.
 
0x2DA4:016
Diagnostics of analog input 1: Status
–
Read only
 
Bit coded display of the status of analog input 1 (X3/AI1).
Bit 0
0 ... 10 VDC active
Bit 1
0 ... 5 VDC active
Bit 2
2 ... 10 VDC active
Bit 3
-10 ... 10 VDC active
Bit 4
4 ... 20 mA active
Bit 5
0 ... 20 mA active
Bit 6
24 V supply OK
Bit 7
Calibration successful
Bit 8
Monitoring threshold exceeded/not reached
Bit 9
Input current too low (4 ... 20 mA)
Bit 10
Input voltage too low (2 ... 10 VDC)
Bit 11
Input voltage too high (4 ... 20 mA)
0x2DA5:001
Diagnostics of analog input 2: Value in percent
–
Read only: x.x %
 
Display of the current input value at X3/AI2 scaled as a value in percent.
–
100 % = 10 V or 20 mA or 5 V
 
0x2DA5:002
Diagnostics of analog input 2: Frequency value
–
Read only: x.x Hz
 
Display of the current input value at X3/AI2 scaled as a frequency value.
–
The standard setpoint source for operating mode 0x6060 = "MS: Velocity mode [-2]" is selected in 0x2860:001.
 
0x2DA5:003
Diagnostics of analog input 2: Process controller value
–
Read only: x.xx PID unit
 
Display of the current input value at X3/AI2 scaled as a process controller value.
–
The standard setpoint source for the reference value of PID control is selected in 0x2860:002.
 
0x2DA5:004
Diagnostics of analog input 2: Torque value
–
Read only: x.x %
 
Display of the current input value at X3/AI2 scaled as a percentage torque value.
–
100 % = permissible maximum torque 0x6072
 
0x2DA5:016
Diagnostics of analog input 2: Status
–
Read only
 
Bit-coded display of the status of analog input 2 (X3/AI2).
Bit 0
0 ... 10 VDC active
Bit 1
0 ... 5 VDC active
Bit 2
2 ... 10 VDC active
Bit 3
-10 ... 10 VDC active
Bit 4
4 ... 20 mA active
Bit 5
0 ... 20 mA active
Bit 6
24 V supply OK
Bit 7
Calibration successful
Bit 8
Monitoring threshold exceeded/not reached
Bit 9
Input current too low (4 ... 20 mA)
Bit 10
Input voltage too low (2 … 10 VDC)
Bit 11
Input voltage too high (4 ... 20 mA)
0x2DAA:001
Diagnostics of analog output 1: Voltage
–
Read only: x.xx V
 
Display of the current output voltage at X3/AO1.
0x2DAA:002
Diagnostics of analog output 1: Current
–
Read only: x.xx mA
 
Display of the present output current at X3/AO1.