Connecting the speed override

Fig. 1: Use of an external speed override
Fig. 2: Control and status bits used
Execution
There are two ways of preselecting a speed override:
1.
Specifying the speed override via the Internal speed override parameter. 0x5030:005
 
2.
Setting the speed override via the External speed override parameter. 0x5030:011
 
The External speed override parameter is activated via bit 13. 0x5030:010 Bit 13
If bit 13 is set, the External speed override parameter is used. The Setpoint speed override parameter indicates what override value has been selected.
0x5032:027.
The values are specified in percent with two decimal positions.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5030:005
Internal velocity override
0.00 ... [100.00] ... 100.00 %
The speed override [%] is set in the range of 0 - 100 %. The speed override has a multiplicative effect on the speed setpoint.
0x5030:011
External velocity override
0.00 ... [0.00] ... 100.00 %
Change of the profile speed during a positioning process.
0x5032:019
Velocity setpoint with offset
–
Read only
 
Setpoint speed with an offset applied is resolved with 4 decimal positions. The setpoint speed is referred to in the unit [unit/s].
0x5032:021
Velocity setpoint
–
Read only
 
0x5032:027
Velocity override setpoint
–
Read only