Inverting the setpoint

Fig. 1: Inversion of the direction of rotation
Fig. 2: Control and status bits used
Execution
The selected setpoint speed is inverted via Active setpoint speed. 0x5032:017
For this purpose, control bit 21 of the control word is provided. 0x5030:010, Bit 22.
If control bit 21 is set to TRUE, the speed setpoint is multiplied by -1. The speed value following the negation position is shown via the Setpoint speed with sign parameter. 0x5032:018
If the axis rotates in the negative direction of rotation, this is indicated via status bit 13. 0x5030:110, bit 13
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5032:017
Active set velocity
–
Read only
 
The speed is resolved with 4 decimal positions. The speed is referred to in the unit [unit/s].
0x5032:018
Set velocity with sign
–
Read only
 
Speed setpoint following the negation position is resolved with 4 decimal positions. The speed setpoint is referred to in the unit [unit/s].
0x5032:028
Set velocity
–
Read only
 
0x5032:029
Direction of rotation inverted
–
Read only
 
 
Example
Fig. 3: Speed setpoint time flow diagram