Inverting the setpoint
Fig. 1: Inversion of the direction of rotation
Fig. 2: Control and status bits used
Execution
The selected setpoint speed is inverted via Active setpoint speed.
0x5032:017
0x5032:017For this purpose, control bit 21 of the control word is provided.
0x5030:010, Bit 22.
0x5030:010, Bit 22.If control bit 21 is set to TRUE, the speed setpoint is multiplied by -1. The speed value following the negation position is shown via the Setpoint speed with sign parameter.
0x5032:018
0x5032:018If the axis rotates in the negative direction of rotation, this is indicated via status bit 13.
0x5030:110, bit 13
0x5030:110, bit 13Parameter
Example
Fig. 3: Speed setpoint time flow diagram