Starting and stopping speed operation

Condition
–
The technology application is in perfect condition.
 
–
The drive is enabled.
 
 
Execution
 order to start a movement with a preselected speed, bit 20 in the control word must be set to TRUE. 0x5030:010, bit 20.
The speed setpoint source corresponds to the source that has been selected via the Set speed setpoint source parameter. 0x5020:002
When control bit  20 has been set, the technology application reports via status bit  20 that speed operation is active. 0x5030:010, Bit 20
The axis now accelerates at the preselected acceleration rate with jerk limitation active (Jerk profile) until the specified setpoint speed is reached. When the setpoint speed has been reached, 10 is set in the status bit. 0x5030:110 Bit 10.
When control bit  20 is set to FALSE, the axis moves to a standstill with the deceleration. This is reported by status bit 12. 0x5030:110 Bit 12.
Fig. 1: Control and status bits used
Parameters to be set: Travel profiles
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5031:003
Velocity profile 0
-214748.3648 ... [0.0000] ... 214748.3647
The speed for profile 0 is resolved with 4 decimal positions.
0x5031:004
Acceleration profile 0
0.00 ... [100.00] ... 21474836.47
The acceleration for profile 0 is resolved with 2 decimal positions.
0x5031:005
Deceleration profile 0
0.00 ... [100.00] ... 21474836.47
The deceleration for profile 0 is resolved with 2 decimal positions.
0x5031:006
Jerk profile 0
0.00 ... [100000.00] ... 21474836.47
The jerk for profile 0 is displayed with 2 decimal positions.
0x5031:023, 034, 045, 056, 067, 078, 089, 100, 111, 122, 133, 144, 155, 166, 177
Profile velocity
-214748.3648 ... [0.0000] ... 214748.3647
Maximum speed at which the target position is approached. The maximum speed depends on the target position, the acceleration and the deceleration.
If the graph is a triangle, the drive has not reach the maximum speed.
1 Acceleration
2 Maximum speed
3 Deceleration
4 Target position
0x5031:024, 035, 046, 057, 068, 079, 090, 101, 112, 123, 134, 145, 156, 167, 178
Profile acceleration
0.00 ... [100.00] ... 21474836.47
Acceleration to reach the maximum speed.
The following acceleration types are distinguished:
–
Linearly increasing acceleration
 
–
Acceleration increasing in S-shape
 
0x5031:025, 036, 047, 058, 069, 080, 091, 102, 113, 124, 135, 146, 157, 168, 179
Profile deceleration
0.00 ... [100.00] ... 21474836.47
Deceleration to brake from the maximum speed to standstill.
0x5031:026, 037, 048, 059, 070, 081, 092, 103, 114, 125, 136, 147, 158, 169, 180
Profile jerk
0.00 ... [100000.00] ... 21474836.47
Jerk limitation for the acceleration and deceleration. If a jerk limitation is given for a travel profile, the acceleration and deceleration are executed via S-shaped ramps.
–
S-shaped ramps protect machine parts from damages.
 
–
The S-shaped acceleration and deceleration extend the duration of positioning compared to linear acceleration and deceleration.
 
Profile without jerk limitation
Profile with jerk limitation
0x5032:012
Active profile: acceleration setpoint
–
Read only
 
The acceleration setpoint is specified in the unit [unit/s2]. The acceleration setpoint is terminated with 2 decimal positions.
0x5032:013
Active profile: deceleration setpoint
–
Read only
 
The deceleration setpoint is specified in the unit [unit/s2]. The deceleration setpoint is terminated with 2 decimal positions.
0x5032:014
Active profile: jerk setpoint
–
Read only
 
The jerk setpoint is specified in the unit [unit/s2]. The jerk setpoint is terminated with 2 decimal positions.
0x5032:015
Active profile: Velocity setpoint
–
Read only
 
The profile setpoint speed is given in the unit [unit/s]. The value of the profile setpoint speed is displayed with 4 decimal positions.
0x5032:025
Selected profile
–
Read only
 
 
Example
Fig. 2: Speed control mode timing diagram