Loading the start diameter
Loading the start diameter has the highest priority.
If the diameter has changed because, for example, a new reel has been inserted, a suitable start diameter must be loaded at the beginning of the following wrapping process.
Setting bit 22 = TRUE of the control word loads the start diameter. 0x5050:010 Bit 22
If bit 22 is held TRUE, the selected value is accepted cyclically. As long as the diameter is set or loaded, the status bit 22 = TRUE remains in the parameter Status signals. 0x5050:110 Bit 22
The following table describes the different use applications to specify the source of the start diameter.
|
Application
|
Source of setpoint diameter 0x5020:022
|
Source of start diameter 0x5051:065
|
|
Start diameter is predefined in the parameter Start diameter.
|
0x5020:022 = any
|
0x5051:065 = 0
|
|
Diameter is specified via the fieldbus Control word DW 1.
|
0x5020:022 = 0
|
0x5051:065 = 1
|
|
Diameter is detected by a sensor at AIN1 of the inverter
|
0x5020:022 = 1
|
0x5051:065 = 1
|
Fig. 1: Selection source of the start diameter
Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
Reference diameter analog input 1
|
1000.0000 mm
|
0.0000 ... 214748.3647 mm
|
|
|
Set diameter source
|
External [0]
|
Selection list
|
|
|
Start diameter source
|
Parameter [0]
|
Selection list
|
|
|
Start diameter
|
100.0000 mm
|
1.0000 ... 10000.0000 mm
|
|
|
External start diameter
|
x.xxxx mm (Read only)
|
||