L_MC1P_BrakeGrindIn

This FB serves to grind a holding brake. This function may be required after the holding brake has been replaced. The holding torque specified in the data sheet is only reached if the friction partners are ground in after mounting.

Supported devices:
  • i700
  • i750
  • i950
Stop!

If this function is activated, the drive is automatically accelerated to the defined grinding speed.

  • The axis must move freely without driving against the travel range limitations.
  • A limited traversing range (active software limit positions) is considered, i.e. the direction is changed automatically several times in order to reach the number of grinding cycles.
  • The maximally permissible friction energy of the holding brake must not be exceeded (observe the specifications of the manufacturer)!

Formula for estimating the friction energy during grinding process

Note!
  • This function can only be started in the " Disabled " axis state ( MC_Power . Enable = FALSE).
  • After the start, it is changed into the " Service " axis state. In this axis state, the drive will be automatically enabled for executing the function.
  • The execution can be aborted via the FB MC_Stop . This causes the drive to be inhibited again.

 

 

 

L_MC1P_BrakeGrindIn

 

 

 

AXIS_REF

-

Axis

xDone

-

BOOL

BOOL

-

xExecute

xBusy

-

BOOL

L_MC1P_GrindInMode

-

eMode

xActive

-

BOOL

L_MC1P_ AdditionalLimits

-

eAdditionalLimits

xCommandAborted

-

BOOL

LREAL

-

IrPosLimit1

xError

-

BOOL

LREAL

-

IrPosLimit2

eErrorID

-

L_IE1P_Error

LREAL

-

lrMotorSpeed

LREAL

-

lrRampTime

LREAL

-

lrOnTime

LREAL

-

lrOffTime

WORD

-

wCycles

BOOL

-

xExternalFan

BOOL

-

xFinishInStartpos

BOOL

-

xUseAxisParameter

 

 

 

 

 

 

 

 

Inputs

Name

Data type

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

xExecute

BOOL

FALSE รค TRUE

Start execution of the function block.

eMode

L_MC1P_GrindInMode

Grinding mode

1

Cw - grinding only in positive direction

2

Ccw - grinding only in negative direction

3

CwCcw - grinding first in positive, then in negative direction

4

CcwCw - grinding first in negative, then in positive direction

eAdditionalLimits

L_MC1P_AdditionalLimits

Activate / deactivate limitation of the grind-in range

Note :

For modulo axes, grinding of the brake is only possible in the NotActive mode.

1

NotActive

No additional limitation of the grinding range by the module. The grinding range is limited by active software limit positions.

2

AdditionalPosLimits

The grinding range is limited by the positions at the lrPosLimit1 and lrPosLimit2 inputs.

IrPosLimit1

LREAL

Selection of the lower position limit in [unit] for grinding in the brake (at the output end).

IrPosLimit2

LREAL

Selection of the upper position limit in [unit] for grinding in the brake (at the output end).

lrMotorSpeed

LREAL

Grinding speed in [min-1] (relating to the motor)

Note:

When grinding in the holding brake it must be ensured that the motor shaft can be held on speed against the applied holding brake. This makes it necessary that the maximum torque of the motor control is greater than the holding torque of the holding brake.

lrRampTime

LREAL

Acceleration and deceleration time in [s]

lrOnTime

LREAL

Runtime in [s]

lrOffTime

LREAL

Downtime in [s]

wCycles

WORD

Number of grind in cycles per direction of movement of the holding brake

If both directions of movement are permitted for the function brake grind in (eMode 3 or 4), then "wCycles" is related to each direction of movement and thus effectively doubled.

xExternalFan

BOOL

The motor or brake is forced ventilated.

The forced ventilated motor or brake enables braking during the downtime. A shorter grinding path is achieved by reducing the speed.

xFinishInStartpos

BOOL

Complete grinding process in the output position

xUseAxisParameter

BOOL

The parameters for executing the function Brake grind in are no longer specified by the FB, but are taken from subindexes 141 ... 147 of the connected AXIS_REF.

The inputs eAdditionalLimits , IrPosLimit1 and IrPosLimit2 are still active.

Outputs

Name

Data type

Value/meaning

xDone

BOOL

TRUE

The command has been executed successfully.

xBusy

BOOL

TRUE

Processing is running.

xActive

BOOL

TRUE

The command of the FB is currently executed.

The xActive output matters if a motion control is carried out by several FBs ( BufferMode ).

xCommandAborted

BOOL

TRUE

The command was cancelled by another FB ( MC_Stop ).

xError

BOOL

TRUE

An error has occurred. For details see eErrorID .

eErrorID

If xError = TRUE: Error number for the error that has occurred.

wCyclesOut

WORD

Number of completed grind in cycles

Procedure in the case of

  • inactive software limit positions
  • eAdditionalLimits = NotActive
  • xExternalFan = FALSE

CINH = controller inhibit

  1. After the execution has started (rising edge at xExecute ), the defined grinding speed lrMotorSpeed is built up via a ramp generator with the lrRampTime acceleration time.
  2. After the grinding speed has been reached, the friction partners in the holding brake are ground by a pulse-type control.
  3. After the given number of application cycles, the direction of rotation is changed and the grinding in the opposite direction is carried out.
  4. If the axis is not to be traversed to its initial position ( xFinishInStartPos = FALSE), it is brought to a standstill via the ramp generator after reaching the defined number of application cycles.
  5. With xFinishInStartPos = TRUE, after reaching the defined number of application cycles, the axis is traversed to the position from which the grinding process has been started.
  6. After the grinding process is completed, the controller is inhibited again automatically.

Note: In the Cw or Ccw mode, grinding of the holding brake only takes place in one direction. The direction can only be reversed if the grinding process is to be completed in the initial position.

Example 1 for mode: CwCcw, wCycles = 3

Procedure in the case of

  • active software limit positions
  • and / or eAdditionalLimits = AdditionalPosLimits
  • xExternalFan = FALSE

CINH = controller inhibit

: End of the traversing range and reversal of the direction

  1. Active software limit positions or the selection of a grinding range ( eAdditionalLimits = AdditionalPosLimits and parameterisation of lrPosLimit1 as well as lrPosLimit2 ), the grinding range is limited.
  2. If the whole grinding process cannot be carried out in the direction parameterised, grinding processes are performed until the limitation is reached. Then the axis is traversed in the opposite direction until the limitation of the grinding range is reached again.
  3. If the lrOffTime parameterised is reached, new grinding processes can be performed in the opposite direction.
  4. If the lrOffTime has not been reached, the axis traverses within the range limits until lrOffTime is reached.
  5. If the direction of rotation of the axis corresponds to the grinding direction, grinding of the brake is carried out immediately after reaching the lrOffTime .
  6. If the direction of rotation of the axis does not correspond to the grinding direction, the axis traverses until the grinding limitation is reached again and then starts the next application cycle in the opposite direction.
  7. Cooling the brake during the lrOffTime can therefore also be effected in the opposite direction.
  8. If the axis is not to be traversed to its initial position ( xFinishInStartPos = FALSE) after reaching the defined number of application cycles, it is brought to a standstill via the ramp generator.
  9. With xFinishInStartPos = TRUE, after reaching the defined number of application cycles, the axis is traversed to the position from which the grinding process has been started.

Note: In the CwCcw and CcwCw modes, the brake can be applied in the reverse direction after the lrOffTime has been reached and before the grinding limitation is reached.

Example 2 for modes: Cw, wCycles = 3

Procedure in the case of

  • inactive software limit positions
  • eAdditionalLimits = NotActive
  • xExternalFan = TRUE

CINH = controller inhibit

  1. After the execution start (rising edge at xExecute ), the preselected grinding speed lrMotorspeed is established via a ramp generator with the lrRampTime acceleration time.
  2. After the grinding speed has been reached, the friction partners in the holding brake are ground by a pulse-type control.
  3. If the lrOffTime is longer than twice the lrRampTime , the axis is braked to a standstill during the cooling period. Then the axis remains at a standstill for the difference of lrRampTime and lrOffTime before the lrMotorspeed grinding speed is increased again via the ramp generator with the lrRampTime acceleration time.
  4. If the lrOffTime is shorter than twice the lrRampTime , the axis is decelerated until half the lrOffTime has elapsed and is then increased to the lrMotorspeed grinding speed again.
  5. When the defined number of application cycles has been performed, the direction of rotation is changed and the grinding process takes place in the opposite direction.
  6. If the axis is not to be traversed to its initial position ( xFinishInStartPos = FALSE), it is brought to a standstill via the ramp generator after reaching the defined number of application cycles.
  7. With xFinishInStartPos = TRUE, after reaching the defined number of application cycles, the axis is traversed to the position from which the grinding process has been started.
  8. After the grinding process is completed, the controller is inhibited again automatically.

Note: In the Cw or Ccw mode, grinding of the holding brake only takes place in one direction. The direction can only be reversed if the grinding process is to be completed in the initial position.

Example 3

Procedure in the case of

  • active software limit positions
  • and / or eAdditionalLimits = AdditionalPosLimits
  • eAdditionalLimits = NotActive
  • xExternalFan = TRUE

CINH = controller inhibit

: End of the traversing range and reversal of the direction

  1. Active software limit positions or the selection of a grinding range ( eAdditionalLimits = AdditionalPosLimits and parameterisation of lrPosLimit1 as well as lrPosLimit2 ), the grinding range is limited.
  2. If the whole grinding process cannot be carried out in the direction parameterised, grinding processes are performed until the limitation is reached. Then the axis is traversed in the opposite direction until the limitation of the grinding range is reached again.
  3. If the lrOffTime has elapsed, the grinding process is continued in the opposite direction.
  4. If the axis is not to be traversed to its initial position ( xFinishInStartPos = FALSE) after reaching the defined number of application cycles, it is brought to a standstill via the ramp generator.
  5. With xFinishInStartPos = TRUE, after reaching the defined number of application cycles, the axis is traversed to the position from which the grinding process has been started.

Note: In the CwCcw and CcwCw modes, the brake can be applied in the reverse direction after the lrOffTime has been reached and before the grinding limitation is reached.

Example 4