L_MC1P_SetSpeedCtrlLoadValue
This FB serves to write the I component of the speed controller of the connected drive. The corresponding bit in the Lenze control word for accepting the I component is automatically set as long as xEnable = TRUE.
Supported devices:
- i700
- i750
- i950
|
Note!
The use of several FB instances for one axis is not recommended, since, generally, only the default value of the FB called last will prevail. |
|
|
|
|
L_MC1P_SetSpeedCtrlLoadValue |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
AXIS_REF |
- |
|
Axis |
xBusy |
|
- |
BOOL |
|
BOOL |
- |
|
xEnable |
xError |
|
- |
BOOL |
|
LREAL |
- |
|
lrSpeedCtrlLoadValue |
eErrorID |
|
- |
L_IE1P_Error |
|
|
|
|
|
|
|
|
|
Motion axes (AXIS_REF)