L_MC1P_SetSpeedCtrlLoadValue

This FB serves to write the I component of the speed controller of the connected drive. The corresponding bit in the Lenze control word for accepting the I component is automatically set as long as xEnable = TRUE.

Supported devices:
  • i700
  • i750
  • i950
Note!

The use of several FB instances for one axis is not recommended, since, generally, only the default value of the FB called last will prevail.

 

 

 

L_MC1P_SetSpeedCtrlLoadValue

 

 

 

AXIS_REF

-

Axis

xBusy

-

BOOL

BOOL

-

xEnable

xError

-

BOOL

LREAL

-

lrSpeedCtrlLoadValue

eErrorID

-

L_IE1P_Error

 

 

 

 

 

 

 

 

Inputs

Name

Data type

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

xEnable

BOOL

TRUE

Write the speed controller I component continuously to the drive.

lrSpeedCtrlLoadValue

LREAL

I component of the speed controller in [Nm]

Outputs

Name

Data type

Value/meaning

xBusy

BOOL

TRUE

Processing is running.

xError

BOOL

TRUE

An error has occurred. For details see eErrorID .

eErrorID

If xError = TRUE: Error number for the error that has occurred.