L_MC1P_GetDigInputsFromDrive

This function provides the state of the digital inputs of the lower-level drive.

 

 

 

L_MC1P_GetDigInputsFromDrive

 

 

 

AXIS_REF

-

Axis

L_MC1P_
GetDigInputsFromDrive

-

DWORD

 

 

 

 

 

 

 

 

Inputs

Name

Data type

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

Outputs

Name

Data type

Value/meaning

L_MC1P_
GetDigInputsFromDrive

DWORD

TRUE

Value of the digital inputs, bit coded

Note!

The Digital Inputs element (0x60FD or 0x68FD) must be transferred as process date of the drive. For the inverter i700 and i950 activate the PDO 16#1A06 or 16#1A16 as follows:

16#1A06 Axis A: Additional stat

Lenze statusword 2 UINT 16#2833:00

Digital inputs UINT 16#60FD:00

Bit

Digital inputs

i550

i700

i950

16

Level at digital input 1

Level at digital input 1

Level at digital input 1

17

Level at digital input 2

Level at digital input 2

Level at digital input 2

18

Level at digital input 3

reserved

Level at digital input 3

19

Level at digital input 4

reserved

Level at digital input 4

20

Level at digital input 5

reserved

Level at digital input 5

21

Level at digital input 6

(only at Application-I/O)

reserved

Level at digital input 6

22

Level at digital input 7

(only at Application-I/O)

reserved

Level at digital input 7

23

reserved

reserved

Level at digital input 8

24

reserved

reserved

Level at digital input 9

25

Internal interconnection digital inputs

reserved

reserved

Bit

Digital input 9400 HighLine CiA402

0

Level at digital input 4 (neg. limit switch)

1

Level at digital input 3 (pos. limit switch)

2

Level at digital input 2 (reference switch)

3

Level at digital input for controller enable

4

Level at digital input 1

(status detection via switching contact)

5

Level at Statebus state

6

Level at digital input 5

7

Level at digital input 6