L_MC1P_BrakeInterface
This FB provides control and status signals of a holding brake control integrated in the AXIS_REF axis data structure.
The holding brake operating mode set in subindex 110 of the axis data structure can be changed temporarily by the FB, e.g. for manually releasing the holding brake.
During automatic operation, this FB is required for
- the output of the state of the brake ( BrakeReleaseOut )
- forced ventilation of the brake ( xReleaseBrake )
- an additional selection of an additive feedforward control value
The brake is controlled via FBs
MC_Power
or
L_MC1P_AxisBasicControl
only.
Supported devices:
- i700
- i750
- i550
|
Danger!
Bear in mind that the holding brake is an important element of the safety concept of the entire machine. Therefore be especially careful when commissioning this system part! |
|
Stop!
Holding brakes on Lenze motors are not intended for braking during operation. The increased wear caused by braking during operation can destroy the motor holding brake! |
|
Please observe the notes in the hardware manual for mounting and electrical installation of the motor holding brake!
Detailed information on the basic function "brake control" can be found in the software manual for the inverter. |
|
|
|
|
L_MC1P_BrakeInterface |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
AXIS_REF |
- |
|
Axis |
xValid |
|
- |
BOOL |
|
BOOL |
- |
|
xEnable |
xBusy |
|
- |
BOOL |
|
BOOL |
- |
|
xReleaseBrake |
xError |
|
- |
BOOL |
|
LREAL |
- |
|
lrTorqueAdd |
eErrorID |
|
- |
L_IE1P_Error |
|
BOOL |
- |
|
xBrakeModeActivate |
xBrakeReleaseOut |
|
- |
BOOL |
|
L_MC1P_BrakeMode |
- |
|
eBrakeMode |
xBrakeReleased |
|
- |
BOOL |
|
|
|
|
|
lrStartingTorqueSaved |
|
- |
LREAL |
|
|
|
|
|
lrStartingTorqueEffective |
|
- |
LREAL |
|
|
|
|
|
eBrakeModeActive |
|
- |
L_MC1P_BrakeMode |
|
|
|
|
|
|
|
|
|
Inputs
|
Name Data type |
Information/possible settings |
|
|---|---|---|
|
Axis |
Transfer of the axis data structure |
|
|
xEnable BOOL |
TRUE |
Start execution of the function block. |
|
xReleaseBrake BOOL |
TRUE |
Manual release of the holding brake in case of manual brake mode or for overriding the automatic mode. |
|
lrTorqueAdd LREAL |
Additional gearbox output side feedforward control torque in [Nm]
|
|
|
xBrakeModeActivate BOOL |
TRUE |
The holding brake mode set in subindex 110 is overwritten with the holding brake mode selected at the eBrakeMode input. The brake state can only be changed if the inverter is closed. |
|
FALSE |
The holding brake mode set in subindex 110 is active. |
|
|
eBrakeMode |
Holding brake mode set if xBrakeModeActivate = TRUE. |
|
Outputs
|
Name Data type |
Value/meaning |
|
|---|---|---|
|
xValid BOOL |
TRUE |
Valid values are applied to the FB outputs. |
|
xBusy BOOL |
TRUE |
Processing is running. |
|
xError BOOL |
TRUE |
An error has occurred. For details see eErrorID . |
|
eErrorID |
If xError = TRUE: Error number for the error that has occurred.
|
|
|
xBrakeReleaseOut BOOL |
FALSE |
Holding brake is triggered for closing. |
|
TRUE |
Holding brake is triggered for opening. |
|
|
xBrakeReleased BOOL |
TRUE |
Holding brake is open (brake opening time has elapsed). |
|
lrActTorque LREAL |
Current torque (at the gearbox output end) in [Nm] |
|
|
lrStartingTorqueSaved LREAL |
Display of the saved starting torque (at the gearbox output end) in [Nm] Setting: Subindex 117 = 0 - last stopping value |
|
|
lrStartingTorqueEffective LREAL |
Display of the effective starting torque (at the gearbox output end) in [Nm] Sum of the active feedforward control torque (depending on the subindex selection 117) plus feedforward control torque at the gearbox output end (input lrTorqueAdd) . |
|
|
eBrakeModeActive |
Display of the active brake mode |
|
Motion axes (AXIS_REF)