L_MC1P_BrakeInterface
- process of the automatic control:
|
|
Servo Inverter i700
- process of the control via device status machine:
|
|
|
When
MC_Power
.
bRegulatorOn
= TRUE, the i700 is enabled and the starting torque for the torque feedforward control is specified simultaneously.
|
|
The "enable operation" command serves to enable the i700 and simultaneously trigger the holding brake to be released.
|
|
|
When the actual torque is = 0.9 x starting torque, the holding brake is triggered to be released. The triggering is signalled at the
xBrakeReleaseOut
output.
|
|
|
After the brake opening time has elapsed, the "holding brake released" status is reported via the
xBrakeReleased
output.
From now on, the Servo Inverter i700 can perform motions.
|
|
After the brake opening time has elapsed, the "holding brake released" status is reported via the CiA402 status word (bit 14).
From now on, the Servo Inverter i700 can perform motions.
|
|
|
When
MC_Power
.
bRegulatorOn
= FALSE, the holding brake is triggered to be closed.
|
|
The "inhibit operation" command serves to trigger the brake to be closed.
|
|
|
Only after the brake closing time has elapsed, the i700 is inhibited. The
xBrakeReleased
output reports the "Holding brake closed" status.
|
|
Only after the brake closing time has elapsed, the i700 is inhibited. The CiA402 status word (bit 14) serves to report the "Holding brake closed" status.
|