L_MC1P_SetInertiaAdaptValue

This FB can be used to adapt the mass moment of inertia for the feedforward control.

Supported devices:
  • i700
  • i750
  • i950
  • Servo Drives 9400 HigLine CiA402
Note!

The use of several FB instances for one axis is not recommended since only the default value of the last called FB is always applied.

 

 

 

L_MC1P_SetInertiaAdaptValue

 

 

 

AXIS_REF

-

Axis

xBusy

-

BOOL

BOOL

-

xEnable

xError

-

BOOL

LREAL

-

lrInertiaAdaptValue

eErrorID

-

L_IE1P_Error

 

 

 

 

 

 

 

 

Inputs

Name

Data type

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

xEnable

BOOL

TRUE

Write adaptation value of mass moment of inertia continuously.

FALSE

The adaptation value remains on the last written value

lrInertiaAdaptValue

LREAL

Adaptation mass moment of inertia

  • Initial value: 1.0 ยบ 100 %
Outputs

Name

Data type

Value/meaning

xBusy

BOOL

TRUE

Execution in progress

xError

BOOL

TRUE

During the processing of the FB, an error has occurred. For details see the eErrorID .

eErrorID