L_MC1P_SetDCBrake

This FB can be used to activate the DC- short-circuit braking function in the inverter.

The activation of this function has no influence on the state machine of the axis. Any necessary interlocking with setpoint-generating functions must be carried out in the application.

In parallel to the execution of this FB, a quick stop can be assigned with the FB L_MC1P_SetQuickStop in order to achieve an interlock to other setpoint generating functions.

Supported devices:
  • i700
  • i750
  • i950

Note! Multiple instances per axis cannot be processed in parallel.

 

 

 

L_MC1P_SetDCBrake

 

 

 

AXIS_REF

-

Axis

xBusy

-

BOOL

BOOL

-

xEnable

xActive

-

BOOL

xError

-

BOOL

eErrorID

-

L_IE1P_Error

 

 

 

 

 

 

 

 

Inputs

Name

Datentyp

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

xEnable

BOOL

FALSE รค TRUE

Start execution of the function block.

Outputs

Name

Datentyp

Value/meaning

xBusy

BOOL

TRUE

Processing is running.

xActive

BOOL

TRUE

The DC-short-circuit braking function is activated in the inverter. The setpoint specification from the application can no longer be followed.

xError

BOOL

TRUE

An error has occurred. For details see eErrorID .

eErrorID

If xError = TRUE: Error number for the error that has occurred.