L_MC1P_SetQuickStop

This FB serves to trigger quick stop in the lower-level drive (e.g. i700).

The quick stop is carried out with the ramp parameterised in the drive (e.g. index 0x6085 of the i700). In this case, the setpoints of the control are not effective, pending following errors are deleted.

With a virtual axis connected to the FB, this axis is stopped with the deceleration of the Axis_Ref error stop (subindexes 48 / 49 ).

 

 

 

L_MC1P_SetQuickStop

 

 

 

AXIS_REF

-

Axis

xBusy

-

BOOL

BOOL

-

xEnable

xActive

-

BOOL

xError

-

BOOL

eErrorID

-

L_IE1P_Error

 

 

 

 

 

 

 

 

Inputs

Name

Data type

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

xEnable

BOOL

FALSE รค TRUE

Start execution of the function block.

Outputs

Name

Data type

Value/meaning

xBusy

BOOL

TRUE

Processing is running.

xActive

BOOL

TRUE

The axis is brought to a standstill via the "Quick stop" function in the drive. If the input xEnable is reset to FALSE during execution of the function, xActive is also reset to FALSE. Setpoint generation in the controller is active again.

xError

BOOL

TRUE

An error has occurred. For details see eErrorID .

eErrorID

If xError = TRUE: Error number for the error that has occurred.