L_MC1P_SetQuickStop
This FB serves to trigger quick stop in the lower-level drive (e.g. i700).
The quick stop is carried out with the ramp parameterised in the drive (e.g. index 0x6085 of the i700). In this case, the setpoints of the control are not effective, pending following errors are deleted.
With a virtual axis connected to the FB, this axis is stopped with the deceleration of the Axis_Ref error stop (subindexes 48 / 49 ).
|
|
|
|
L_MC1P_SetQuickStop |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
AXIS_REF |
- |
|
Axis |
xBusy |
|
- |
BOOL |
|
BOOL |
- |
|
xEnable |
xActive |
|
- |
BOOL |
|
|
|
|
|
xError |
|
- |
BOOL |
|
|
|
|
|
eErrorID |
|
- |
L_IE1P_Error |
|
|
|
|
|
|
|
|
|
Inputs
|
Name Data type |
Information/possible settings |
|
|---|---|---|
|
Axis |
Transfer of the axis data structure |
|
|
xEnable BOOL |
FALSE รค TRUE |
Start execution of the function block. |
Motion axes (AXIS_REF)