L_MC1P_CinhHandling
This FB can be used to hide an STO event that has occurred in the inverter for the application. This overrides the setting made via subindex 107 - Response - inverter disabled in operation. The Axis_Ref continues to report the state that was active before the STO event occurred and does not change to the ERROR or DISABLED state. Consequently, the technology module or axis group connected to the axis also remains in its original state.
If STO is canceled again, the interconnection is still error-free and the execution of the program can be continued without further actions.
Prerequisite
Before the STO event occurs, the setpoint generation must be stopped, i.e. the setpoint speed must assume the value 0.
- This behavior can be used to be able to resume the machine process after a known EMERGENCY STOP event has disappeared.
Supported devices:
- i550 (device version with STO terminal)
- i700
- i750
- i950
- 9400 with SM30x (controller inhibit via terminal, STO via SM30x)
- 9400 with SM100 (controller inhibit via terminal, for STO via SM100 a change to the application in the 9400 is necessary)
|
|
|
|
L_MC1P_CinhHandling |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
AXIS_REF |
- |
|
Axis |
xDone |
|
- |
BOOL |
|
BOOL |
- |
|
xEnable |
xBusy |
|
- |
BOOL |
|
BOOL |
- |
|
xStayInLastState |
xError |
|
- |
BOOL |
|
BOOL |
- |
|
xMoveLastSetPos |
eErrorID |
|
- |
L_IE1P_Error |
|
LREAL |
- |
|
IrWindowPos |
xReadyToContinue |
|
- |
BOOL |
|
LREAL |
- |
|
IrWindowNeg |
xInsidePosWindow |
|
- |
BOOL |
|
LREAL |
- |
|
IrSetVel |
xInsideActPosWindow |
|
- |
BOOL |
|
LREAL |
- |
|
IrSetAcc |
eAxisStateReal |
|
- |
L_MC1P_AXIS_STATE |
|
LREAL |
- |
|
IrSetDec |
IrDistance |
|
- |
LREAL |
|
LREAL |
- |
|
IrSetJerk |
|
|
|
|
|
MC_Direction |
- |
|
eDirection |
|
|
|
|
|
|
|
|
|
|
|
|
|
Inputs
|
Negative |
||
|
ShortestWay |
||
|
Positive / Negative Cycle |
not supported |
|
Outputs
|
Name Data type |
Information/possible settings |
|
|---|---|---|
|
xDone BOOL |
TRUE |
The command has been executed successfully. |
|
xBusy BOOL |
TRUE |
Processing is running. |
|
xError BOOL |
TRUE |
An error has occurred. For details see eErrorID . |
|
eErrorID |
If xError = TRUE: Error number for the error that has occurred.
|
|
|
xReadyToContinue BOOL |
TRUE |
The axis is ready to react to a setpoint specification. Any positioning via xMoveLastSetPos is completed. This signal is required because the feedback signals via the existing status signals ( eAxisState , xAxisReadyForMotion ) no longer reflect the actual axis status when xStayInLastState is activated. |
|
xInsidePosWindow BOOL |
TRUE |
Actual position is within the window defined at the inputs lrWindowPos and lrWindowNeg . If the window is parameterized to 0, the signal is permanently TRUE. |
|
xInsideActPosWindow BOOL |
TRUE |
Actual position is within the parameterized window (subindex 136 / 137 ) |
|
eAxisStateReal |
Real state of the axis |
|
|
IrDistance LREAL |
Distance of the actual position from the setpoint position at the time of interruption, i.e. when the STO event occurs. The actual distance incl. modulo overflows is displayed in the modulo dimension system. |
|