L_MC1P_CinhHandling

This FB can be used to hide an STO event that has occurred in the inverter for the application. This overrides the setting made via subindex 107 - Response - inverter disabled in operation. The Axis_Ref continues to report the state that was active before the STO event occurred and does not change to the ERROR or DISABLED state. Consequently, the technology module or axis group connected to the axis also remains in its original state.

If STO is canceled again, the interconnection is still error-free and the execution of the program can be continued without further actions.

Prerequisite

Before the STO event occurs, the setpoint generation must be stopped, i.e. the setpoint speed must assume the value 0.

  • This behavior can be used to be able to resume the machine process after a known EMERGENCY STOP event has disappeared.
Supported devices:
  • i550 (device version with STO terminal)
  • i700
  • i750
  • i950
  • 9400 with SM30x (controller inhibit via terminal, STO via SM30x)
  • 9400 with SM100 (controller inhibit via terminal, for STO via SM100 a change to the application in the 9400 is necessary)

 

 

 

L_MC1P_CinhHandling

 

 

 

AXIS_REF

-

Axis

xDone

-

BOOL

BOOL

-

xEnable

xBusy

-

BOOL

BOOL

-

xStayInLastState

xError

-

BOOL

BOOL

-

xMoveLastSetPos

eErrorID

-

L_IE1P_Error

LREAL

-

IrWindowPos

xReadyToContinue

-

BOOL

LREAL

-

IrWindowNeg

xInsidePosWindow

-

BOOL

LREAL

-

IrSetVel

xInsideActPosWindow

-

BOOL

LREAL

-

IrSetAcc

eAxisStateReal

-

L_MC1P_AXIS_STATE

LREAL

-

IrSetDec

IrDistance

-

LREAL

LREAL

-

IrSetJerk

MC_Direction

-

eDirection

 

 

 

 

 

 

 

 

Inputs

Negative

ShortestWay

Positive / Negative Cycle

not supported

Outputs

Name

Data type

Information/possible settings

xDone

BOOL

TRUE

The command has been executed successfully.

xBusy

BOOL

TRUE

Processing is running.

xError

BOOL

TRUE

An error has occurred. For details see eErrorID .

eErrorID

If xError = TRUE: Error number for the error that has occurred.

xReadyToContinue

BOOL

TRUE

The axis is ready to react to a setpoint specification.

Any positioning via xMoveLastSetPos is completed.

This signal is required because the feedback signals via the existing status signals ( eAxisState , xAxisReadyForMotion ) no longer reflect the actual axis status when xStayInLastState is activated.

xInsidePosWindow

BOOL

TRUE

Actual position is within the window defined at the inputs lrWindowPos and lrWindowNeg .

If the window is parameterized to 0, the signal is permanently TRUE.

xInsideActPosWindow

BOOL

TRUE

Actual position is within the parameterized window (subindex 136 / 137 )

eAxisStateReal

L_MC1P_AXIS_STATE

Real state of the axis

IrDistance

LREAL

Distance of the actual position from the setpoint position at the time of interruption, i.e. when the STO event occurs.

The actual distance incl. modulo overflows is displayed in the modulo dimension system.