Virtual mode Activation (subindex 29 )

Virtual axis Encoder 9400 HighLine i700 servo inverter i500 inverter i950 servo inverter

Virtual mode activation
  • This parameter serves to virtually switch a motion axis that is connected to a real drive.
  • The axis then behaves like a virtual axis and the state of the connected real drive is ignored.
  • This option can be used if the real axis is not available on the EtherCAT bus but is to be used in the project, e.g. as master axis or for testing the program execution.

Selection list (Lenze setting printed in bold)

Info

0

Inactive

not active

1

Active

Active

Read access Write access Can only be changed in "Disabled" state No download

UNSIGNED_8