Position resolution (subindex 36 )

Virtual axis Encoder 9400 HighLine i700 servo inverter i500 inverter i950 servo inverter

Resolution of an encoder revolution
  • This parameter serves to set the resolution used by the position signal of the lower-level drive.
  • The resolution of an encoder revolution is set as default to 65536 increments/revolution.
  • The possible settings depend on the lower-level drive.
    • Inverters i700 and i950: The set value must be identical to device parameter 0x608F subindex 1 (encoder increments), or 0x688F subindex 1 for axis B.
    • Inverter 9400HL CiA402: The set value must be identical to code C00100 (resolution of one encoder revolution) and C02524 (feed constant).
    • When using Lenze inverters, AxisRef writes the value to the respective parameters of the drive during startup or when changing.

Selection list (Lenze setting printed in bold)

Info

65536

2^16 (16 bit)

2^16 (16 bit)

262144

2^18 (18 bit)

2^18 (18 bit)

1048576

2^20 (20 bit)

2^20 (20 bit)

4194304

2^22 (22 bit)

2^22 (22 bit)

16777216

2^24 (24 bit)

2^24 (24 bit)

67108864

2^26 (26 bit)

2^26 (26 bit)

268435456

2^28 (28 bit)

2^28 (28 bit)

1073741824

2^30 (30 bit)

2^30 (30 bit)

Read access Write access Can only be changed in "Disabled" state No download

UNSIGNED_32