Automatic stop

The automatic stop function is enabled with parameter eTensCtrlStopMode = 4 and in mode eTensCtrlMode = 2 VelocityMaster. With input xTensCtrl = TRUE the winding mode is enabled. Here the TM is used in velocity master mode - at output lrSetLineVelOut the line velocity is calculated.

The automatic stop is activated, if by the deceleration of the line with the profile parameters lrSyncLineDec and lrLineJerk the counter value of the material length counter lrTargetMaterialCounter is reached. The TM reaches standstill and remains in the state WINDING until the input xTensCtrl = TRUE is set. During the deceleration phase and at standstill the status xStopLine = TRUE is set.

With xTensCtrl = FALSE the state STANDBY is set and the TM may resume the winding operation.

Special case

  • The winder is winding in the invalid direction and the desired counter value of the material length counter scPar.lrTargetMaterialCounter cannot be reached. In this case a warning at TM output xWarning = TRUE is activated (eErrorID = TargetMaterialCounterNotReached).

The mode eTensCtrlStopMode = 4 is activated but the winder is not operated in the mode "Velocity Master" (eTensCtrlMode <> 2). In this case a warning at output xWarning = TRUE is activated (eErrorID = InvalidStopMode). In this case the winder function is terminated via the stop mode eTensCtrlStopMode = 0 (stop).