Reduced controller dynamics at low system deviation

A reduced dynamic performance of the controller with minor system deviations in most cases has a beneficial influence on the control loop damping behaviour.

The system deviation results from the difference between the setpoint value and the actual value, i.e. the difference between the lrSetTens input and the lrActTensIn output.

The lrReducedGain parameter serves to set the value to which the gain is to be reduced in the defined tolerance zone. This means, in the tolerance zone, the reduced gain is active (lrReducedGain).

Parameters to be set

Identifier

Data type

Description

 

lrReducedGainWindow

LREAL

Area of the system deviation with a reduced gain / sensitivity.

The lrReducedGainWindow parameter is used to set a tolerance range in which the system deviation is transmitted to the controller with a lower gain. The tolerance range is set above and below the setpoint.

  • Initial value: 0.0

lrReducedGain

LREAL

System deviation gain within the reduced sensitivity range

The lrReducedGain parameter serves to set the value to which the gain is to be reduced in the defined tolerance zone. This means, in the tolerance zone, the reduced gain is active (lrReducedGain).

  • Initial value: 0.0