Speed limitation

The speed limitation is only relevant for torque-based operation. The torque-based operation is set with the eTensCtrlMode parameter = 0 ("TorqueBased").

Speed limitation in closed-loop/open-loop tension control mode

In the closed-loop/open-loop tension-controlled operation mode with mounted material, the winder speed is determined by the circumferential speed and the current diameter. Speed limitation must take effect in the event of a web break or an overcompensation of a disturbance and prevent the reel from being accelerated towards nmax.

The scPar.lrLineVelOffsetScaled parameter is used to determine a percentage lead (reference variable scPar.lrLineVelRef = 100%) in relation to the current line speed lrSetLineVel that can, however, never be achieved when material is mounted in the system.

It is not generally necessary to change the default limitation threshold value of 10% (scPar.lrLineVelOffsetScaled = 0.10).

The currently effective limitation threshold values can be diagnosed in MP_lrSetUpperSpeedLimit and MP_lrSetLowerSpeedLimit.

If the limitation threshold and consequently speed regulation become active, the status xWndSpdLimit = TRUE is set at the output.

Speed limitation in the event of a web break

Danger!

Injury to persons and damage or destruction of machine parts

Injury to persons and damage or destruction of machine parts is caused by unpredictable motor movements, especially by too high velocities.

Possible consequences

Death or severe injuries

Protective measures

On an unwinder, an overcompensation of friction and/or acceleration should be avoided at all costs!

Speed limitation can also not prevent the generation of material slack. This results in the diameter approaching Dmin and the winder rotating even faster (positive feedback).

For the speed limitation in torque-controlled operation, the speed offset is converted separately into a rotational speed offset by multiplying by 1/d. This value is added to / subtracted from the speed setpoint to calculate the upper and lower speed limits.

During normal operation, the calculated diameter values are continuously rising (rewinder) or falling (unwinder). A web break leads to a change of direction in the diameter calculation.

In this process, the diameter of the rewinder may approach Dmin, which, without speed limitation, would cause the winder to accelerate up to nmax.

On an unwinder, a web break would cause the diameter to approach DMax. If speed limitation is implemented, the speed in the winding direction will not exceed the configured scPar.lrLineVelOffsetScaled, assessed with the current diameter.

Parameters to be set

See also: L_TW2P_scPar_WinderTensionCtrlState basic functions

Identifier

Data type

Description

lrLineVelRef

LREAL

Maximum line velocity

  • Unit: mm/s

  • Initial value: 1000

lrLineVelOffsetScaled

LREAL

Line speed offset for speed limitation

  • Unit: x 100 % (1 = 100 % = lrLineVelRef parameter)

  • Initial value: 0.1