Web break monitoring
In the case of a web break, the diameter calculated develops in the opposite direction of the winding direction (unwinding or rewinding), since the actual circumferential speed no longer corresponds to the line speed signal.
The monitoring function is activated with the xWebBreakMonit input = TRUE, making a diameter change opposed to the winding direction only permissible within the window set in the lrWebBreakWindow parameter.
Rewinding or unwinding is automatically detected via the sign of the line velocity and the winding direction set via the xWindingDirection input.
-
Web break monitoring may only be activated when the calculated diameter corresponds to the real diameter.
If web break monitoring is activated (xWebBreakMonit = TRUE), a diameter change contrary to the winding direction specified via the xUnwind output.
After loading a starting diameter which deviates considerably from the real diameter contrary to the winding direction, this may lead to an unintentional triggering of the monitoring function. If, for instance, a starting diameter of 50% is loaded for a rewinder and the real diameter only is 45%, then a change of the diameter value to the real 45 % is prevented when web break monitoring is activated.
Parameters to be set
|
Identifier Data type |
Description |
|---|---|
|
lrWebBreakWindow LREAL |
Web break window The current diameter is compared to the previous diameter across the web break window from the last calculation cycle.
|