Landing calculator

Prerequisites for activating the function

  • Material length counter is parameterized and activated.

  • The landing function is independent of the winding mode.

  • The landing calculator is activated together with the material length counter.

The landing calculator function is always calculated together with the material length counter. The function is activated as soon as the parameter scPar.lrSyncLineDec > 0 is set.

The counter reading of the material length counter is displayed at the measuring point MP_lrTargetMaterialCounterStopLine.

The counter reading is calculated from the extrapolation when the line is brought to a standstill with the profile parameters lrSyncLineDec and lrLineJerk. The calculation is cyclic, also in the deceleration phase of the line.

The status xStopLine = TRUE is set if the deceleration phase is started into standstill with the profile parameters lrSyncLineDec and lrLineJerk. The material counter lrMaterialCounter reaches the value scPar.lrTargetMaterialCounter.