0x2310:001
|
Direct Parameter Page1: Master command
–
Read only
–
From version 05.04
|
Status display of the "Master Command".
|
|
0x2310:002
|
Direct Parameter Page1: Master cycle time
–
Read only
–
From version 05.04
|
Current cycle time with which the master responds to the device. Can be used as parameter for monitoring the process data transfer.
|
|
0x2310:003
|
Direct Parameter Page1: Minimum cycle time
–
Read only
–
From version 05.04
|
Minimum cycle time supported by the device. This is a performance feature of the device and depends on its technology and implementation.
|
|
0x2310:004
|
Direct Parameter Page1: M-sequence capability
–
Read only
–
From version 05.04
|
Information on the implemented options with regard to the M sequences and the physical configuration.
|
|
0x2310:005
|
Direct Parameter Page1: Revision ID
–
Read only
–
From version 05.04
|
ID of the IO-Link protocol version used for the implementation. 0x11 (used version 1.1)
|
|
0x2310:006
|
Direct Parameter Page1: Process data input
–
Read only
–
From version 05.04
|
Input data from the IO-Link device to the IO-Link master.
|
|
0x2310:007
|
Direct Parameter Page1: Process data output
–
Read only
–
From version 05.04
|
Output data from the IO-Link master to the IO-Link device.
|
|
0x2310:008
|
Direct Parameter Page1: Vendor ID
–
Read only
–
From version 05.04
|
Display of the manufacturer ID.
|
|
0x2310:009
|
Direct Parameter Page1: Device ID
0 ... [0] ... 4294967295
|
Display of the device ID.
|
|
0x2310:010
|
Direct Parameter Page1: Function ID
–
Read only
–
From version 05.04
|
Display of the function ID.
|