IO-Link event IDs

The IO-Link error codes differ from the Lenze error codes. According to the IO-Link specification, manufacturer-specific "error codes" are listed in the following table.
–
Clicking the details of the error code shows you a detailed description of the error message.
 
–
If the inverter indicates an "internal error" that is not listed here, restart the inverter. If the error persists, make a note of the error code and contact the manufacturer.
 
 
Event ID
Event
Severity
Details
0x1801
CiA: Continuous over current (internal)
Fault
0x1802
Short circuit or earth leakage at the motor end
Fault
0x1803
Short circuit at the motor end
Fault
0x1804
CiA: i²xt overload (thermal state)
Fault
0x1805
Fault - Device utilization (ixt) too high
Fault
0x1806
Warning - Device utilization (ixt) too high
Warning
0x1807
Clamp responded too often
Fault
0x1808
Sensorless control: stall detection active
Trouble
0x1809
Maximum current reached
Information
0x180A
Mains phase fault
Fault
0x180B
UPS operation active
Warning
0x180C
Fault - DC bus overvoltage
Fault
0x180D
DC bus overvoltage warning
Warning
0x180E
Fault - DC bus undervoltage
Trouble
0x180F
DC bus undervoltage warning
Warning
0x1810
DC-bus voltage too low for power up
Warning
0x1811
Fault - Power unit overtemperature
Fault
0x1812
Fault - Heat sink temperature sensor
Fault
0x1813
Heat sink fan warning
Warning
0x1814
PU overtemperature warning
Warning
0x1815
Motor overtemperature
Fault
0x1816
External supply voltage critical
Warning
0x1817
Overload 24 V supply
Warning
0x1818
OEM hardware incompatible
Fault
0x1820
Warning - Internal fan
Warning
0x182A
Trigger/functions connected incorrectly
Trouble
0x182B
User-defined fault 1
Fault
0x182C
User-defined fault 2
Fault
0x182D
Warning invert rotation
Warning
0x182E
Maximuml allowed troubles exceeded
Fault
0x182F
User-defined fault (LECOM)
Fault
0x1830
Network: user fault 1
Fault
0x1831
Network: user fault 2
Fault
0x1832
NetWordIN1 configuration incorrect
Trouble
0x1890
Changed device ID not yet active
Fault
0x1891
Default settings not yet active
Fault
0x1834
CU: load error ID tag
Fault
0x1835
PU: load error ID tag
Fault
0x1836
Power unit unknown
Fault
0x1838
Assertion level monitoring (Low/High)
Fault
0x1839
Analog input 1 fault
Fault
0x183A
Analog input 2 fault
Fault
0x183B
HTL input fault
No response
0x183C
Analog output 1 fault
Warning
0x183D
Analog output 2 fault
Warning
0x183E
Fault - Pole position identification
Fault
0x183F
Motor overcurrent
Fault
0x1840
Encoder open circuit
Warning
0x1841
Feedback system: speed limit
Warning
0x1842
Memory module is full
Warning
0x1843
Memory module not present
Fault
0x1844
Invalid user data
Fault
0x1845
Data not compl. saved before powerdown
Warning
0x1848
Memory module: invalid OEM data
Warning
0x1849
Memory module: wrong type
Fault
0x184A
EPM firmware version incompatible
Fault
0x184B
EPM data: firmware type incompatible
Fault
0x184C
EPM data: new firmware type detected
Fault
0x184D
EPM data: PU size incompatible
Fault
0x184E
EPM data: new PU size detected
Fault
0x184F
Invalid parameter changeover configuration
Warning
0x1850
EPM data: unknown parameter found
Information
0x1851
Parameter changes lost
Fault
0x1852
Network - Time-out explicit message
Warning
0x1853
Network - Overall communication time-out
Warning
0x1854
Time-out (PAM)
No response
0x1855
Modbus TCP master time-out
Fault
0x1856
Modbus TCP Keep Alive time-out
Fault
0x1858
CAN: bus off
Trouble
0x1859
CAN: warning
Warning
0x185A
CAN: heartbeat time-out consumer 1
Fault
0x185B
CAN: heartbeat time-out consumer 2
Fault
0x185C
CAN: heartbeat time-out consumer 3
Fault
0x185D
CAN: heartbeat time-out consumer 4
Fault
0x185E
Network - Watchdog time-out
Trouble
0x185F
Network - Disruption of cyclic data exchange
No response
0x1860
Network - Initialization error
Trouble
0x1861
Network - Invalid cyclic process data
Trouble
0x1863
Modbus: network time-out
Fault
0x1864
Modbus: incorrect request by master
Warning
0x1865
Network communication faulty
Trouble
0x1866
POWERLINK: Loss of SoC
Trouble
0x1867
POWERLINK: CRC error
Trouble
0x1868
Network - PDO mapping error
Trouble
0x1869
CAN: RPDO1 time-out
Fault
0x186A
CAN: RPDO2 time-out
Fault
0x186B
CAN: RPDO3 time-out
Fault
0x186C
Torque limit reached
No response
0x186D
Function not allowed in selected operating mode
Warning
0x186E
Keypad removed
Fault
0x186F
Fault - Brake resistor overload
Fault
0x1870
Safe torque off (STO) activated
Fault
0x1871
Motor overspeed
Fault
0x1872
Motor phase missing
No response
0x1873
Motor phase failure phase U
No response
0x1874
Motor phase failure phase V
No response
0x1875
Motor phase failure phase W
No response
0x1876
Motor parameter identification fault
Fault
0x1877
FMF Error
Fault
0x188F
Cascading overload
Warning
0x187E
Warning - Brake resistor overload
Warning
0x187F
Automatic start disabled
Fault
0x1880
Load loss detected
No response
0x1881
Motor overload
No response
0x1882
Maximum motor frequency reached
Warning
0x188c
Manual mode disabled
Warning
0x188d
Manual mode activated
Warning
0x188e
Manual mode time-out
Fault
Safety option - Internal error
Fault
0x1883
Wrong password
Warning
0x1884
Warning
Warning
0x1885
Fatal Error
Fault
0x1886
Power unit fatal error
Fault
0x1888
Keypad full control active
Warning