Example: Enable inverter
This example shows how to use the "Enable inverter" function for a separate enable input.
–
In sleep mode of switch S1 (normally-closed contact), "Enable inverter" is already available.
–
Switch S2 starts the motor in forward rotating direction (if switch S1 is closed). Switch S2 in initial position stops the motor again.
–
Switch S1 disables the inverter. The motor has no torque (is coasting).
|
Connection diagram
|
Function
|
||
|
|
|
Switch S1
|
Disable inverter
|
|
Switch S2
|
Run
|
||
|
Parameter
|
Name
|
Setting for this example
|
|
Plug X3.1 configuration
|
DI2 + DI1 [1]
|
|
|
Enable inverter
|
Digital input 1 [11])
|
|
|
Run
|
Digital input 2 [12]
|
|
|
Reset fault
|
Not connected [0]
|
|
|
Frequency control: Default setpoint source
|
Frequency preset 2 [12]
|
|
|
Frequency setpoint presets: Preset 2
|
40.0 Hz
|
|
The status signals can be assigned to digital outputs.
Configure digital outputs |
|
|
|
|
|
①
|
If the inverter is enabled and no error is active, the motor can be started with the "Run" function in forward rotating direction.
|
|
②
|
If "Enable inverter" is set to FALSE, the inverter is disabled. The motor has no torque and coasts to standstill depending on the mass inertia of the machine.
|
|
③
|
Without "Enable inverter", the motor cannot be started.
|
|
④
|
In the default setting, the motor does not start if the "Run" function is set to TRUE during "Enable inverter". After "Enable inverter". "Run" must be retriggered to start the motor.
|
Configure digital outputs