Trigger list
The trigger list lists all selection options (triggers) for the functions which can be configured using the parameters 0x2631:xxx.
|
Selection
|
Information
|
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
1
|
Constant TRUE
|
Trigger is constantly TRUE.
|
|
11
|
Digital input 1
|
State of X3/DI1, taking an inversion set in 0x2632:001 into consideration.
|
|
12
|
Digital input 2
|
State of X3/DI2, taking an inversion set in 0x2632:002 into consideration.
|
|
13
|
Digital input 3
|
State of X3/DI3, taking an inversion set in 0x2632:003 into consideration.
|
|
14
|
Digital input 4
|
State of X3/DI4, taking an inversion set in 0x2632:004 into consideration.
|
|
15
|
Digital input 5
|
State of X3/DI5, taking an inversion set in 0x2632:005 into consideration.
|
|
16
|
Digital input 6
|
State of X3/DI6, taking an inversion set in 0x2632:006 into consideration.
|
|
17
|
Digital input 7
|
State of X3/DI7, taking an inversion set in 0x2632:007 into consideration.
|
|
18
|
Digital input 8
|
State of X3/DI8, taking an inversion set in 0x2632:008 into consideration.
|
|
50
|
Running
|
TRUE if inverter and start are enabled and output frequency > 0 Hz. Otherwise FALSE.
Exception, quick stop mode: TRUE if inverter and start are enabled and output frequency > 0.2 Hz. Otherwise FALSE.
|
|
51
|
Ready for operation
|
TRUE if inverter is ready for operation (no error active, no STO active and DC-bus voltage ok). Otherwise FALSE.
|
|
53
|
Stop active
|
TRUE if inverter is enabled and motor is not started and output frequency = 0.
|
|
54
|
Quick stop active
|
TRUE if quick stop is active. Otherwise FALSE.
|
|
58
|
Device warning active
|
TRUE if warning is active. Otherwise FALSE.
–
A warning has no impact on the operating status of the inverter.
–
A warning is reset automatically if the cause has been eliminated.
|
|
59
|
Device trouble active
|
TRUE if a fault is active. Otherwise FALSE.
–
In the event of a fault, the motor is brought to a standstill with the quick stop ramp. The inverter is then disabled.
–
Exception: In case of a serious fault, the inverter is disabled immediately. The motor has no torque (coasts).
–
The error state will be left automatically if the error condition is not active anymore.
–
The restart behaviour after trouble can be configured.
Automatic restart after a fault |
|
60
|
Heatsink temperature warning active
|
TRUE if current heatsink temperature > warning threshold for temperature monitoring. Otherwise FALSE.
–
Display of the current heatsink temperature in 0x2D84:001.
–
Setting of the warning threshold in 0x2D84:002.
|
|
68
|
Stop command active
|
TRUE if delay to standstill active. Otherwise FALSE.
|
|
69
|
Rotational direction reversed
|
TRUE if output frequency is negative. Otherwise FALSE.
|
|
70
|
Frequency threshold exceeded
|
TRUE if current output frequency > frequency threshold. Otherwise FALSE.
|
|
71
|
Actual speed = 0
|
TRUE if actual output frequency = 0 Hz (
± 0.3 Hz), irrespective of the operating mode. Otherwise FALSE. |
|
78
|
Current limit reached
|
TRUE if current motor current
≥ maximum current. Otherwise FALSE. |
|
79
|
Torque limit reached
|
TRUE if torque limit has been reached or exceeded. Otherwise FALSE.
–
Setting "Actual positive torque limit" in 0x2949:003.
–
Setting "Actual negative torque limit" in 0x2949:004.
|
|
81
|
Error of analog input 1 active
|
TRUE if the monitoring of the input signal at the analog input 1 has responded. Otherwise FALSE.
This trigger is set as a function of the following settings:
–
Monitoring threshold 0x2636:008
–
Monitoring condition 0x2636:009
The setting of the Error response in 0x2636:010 has no effect on this trigger.
|
|
82
|
Error of analog input 2 active
|
TRUE if the monitoring of the input signal at the analog input 2 has responded. Otherwise FALSE.
This trigger is set as a function of the following settings:
–
Monitoring threshold 0x2637:008
–
Monitoring condition 0x2637:009
The setting of the Error response in 0x2637:010 has no effect on this trigger.
|
|
83
|
Load loss detected
|
TRUE if actual motor current < threshold for load loss detection after delay time of the load loss detection has elapsed. Otherwise FALSE.
–
Display of the actual current in 0x6078.
–
Setting Threshold in 0x4006:001.
–
Setting Delay time in 0x4006:002.
|
|
84
|
Heavy load monitoring
|
TRUE if the actual apparent current of the motor exceeds the threshold for longer than the delay time.
FALSE if the actual apparent current of the motor falls below the threshold value minus 5 % (hysteresis).
|
|
120
|
Homing active
|
Status signals output by the "Table positioning" function.
–
These selection options are only available for the I65AMxxxxxxxxxP product variant.
|
|
121
|
Homing done
|
|
|
122
|
Manual jog active
|
|
|
123
|
Halt active
|
|
|
124
|
Motor control in limitation
|
|
|
125
|
Set position reached
|
|
|
126
|
Abort active
|
|
|
127
|
Standstill
|
|
|
128
|
Active profile (bit 1)
|
|
|
129
|
Active profile (bit 2)
|
|
|
130
|
Active profile (bit 3)
|
|
|
131
|
Active profile (bit 4)
|
|
|
132
|
Positioning profile active
|
|
|
133
|
Positioning profile done
|
|
|
134
|
Negative hardware limit switch active
|
|
|
135
|
Positive hardware limit switch active
|
|
|
136
|
Touch probe detected
|
|
|
137
|
External position active
|
|
|
169
|
Logic PLC Out bit 0
|
Binary values output by the integrated Logic PLC.
–
These selection options are only available for the I65AMxxxxxxxxxP product variant.
|
|
170
|
Logic PLC Out bit 1
|
|
|
171
|
Logic PLC Out bit 2
|
|
|
172
|
Logic PLC Out bit 3
|
|
|
173
|
Logic PLC Out bit 4
|
|
|
174
|
Logic PLC Out Bit 5
|
|
|
175
|
Logic PLC Out Bit 6
|
|
|
176
|
Logic PLC Out bit 7
|
|
|
177
|
Logic PLC Out bit 8
|
|
|
178
|
Logic PLC Out bit 9
|
|
|
179
|
Logic PLC Out bit 10
|
|
|
180
|
Logic PLC Out bit 11
|
|
|
181
|
Logic PLC Out bit 12
|
|
|
182
|
Logic PLC Out bit 13
|
|
|
183
|
Logic PLC Out bit 14
|
|
|
184
|
Logic PLC Out bit 15
|
|
|
224
|
IOL1 BI1 value
|
Binary values received via IO-Link corresponding to the binary input configuration for the respective IO-Link port.
–
The function assignment of the connectors must be configured accordingly.
–
The IO-Link ports are only available on the inverter with Application-I/O.
|
|
225
|
IOL1 BI2 value
|
|
|
226
|
IOL1 BI3 value
|
|
|
227
|
IOL1 BI4 value
|
|
|
228
|
IOL1 BI5 value
|
|
|
229
|
IOL1 BI6 value
|
|
|
230
|
IOL1 BI7 value
|
|
|
231
|
IOL1 BI8 value
|
|
|
232
|
IOL2 BI1 value
|
|
|
233
|
IOL2 BI2 value
|
|
|
234
|
IOL2 BI3 value
|
|
|
235
|
IOL2 BI4 value
|
|
|
236
|
IOL2 BI5 value
|
|
|
237
|
IOL2 BI6 value
|
|
|
238
|
IOL2 BI7 value
|
|
|
239
|
IOL2 BI8 value
|
|
|
240
|
IOL3 BI1 value
|
|
|
241
|
IOL3 BI2 value
|
|
|
242
|
IOL3 BI3 value
|
|
|
243
|
IOL3 BI4 value
|
|
|
244
|
IOL3 BI5 value
|
|
|
245
|
IOL3 BI6 value
|
|
|
246
|
IOL3 BI7 value
|
|
|
247
|
IOL3 BI8 value
|
|
|
248
|
IOL4 BI1 value
|
|
|
249
|
IOL4 BI2 value
|
|
|
250
|
IOL4 BI3 value
|
|
|
251
|
IOL4 BI4 value
|
|
|
252
|
IOL4 BI5 value
|
|
|
253
|
IOL4 BI6 value
|
|
|
254
|
IOL4 BI7 value
|
|
|
255
|
IOL4 BI8 value
|
|
Automatic restart after a fault