Binary input configuration

Selection and configuration of binary values received via IO-Link for use within the inverter.
 
Details
Individual bits of the IO-Link process input data can be mapped to internal variables, so-called "binary inputs". The binary inputs can be used for control tasks. For this purpose, the binary inputs are available as selectable triggers for functions.
–
8 binary inputs are available for each IO-Link port.
 
–
For each binary input, there is a parameter object that can be assigned to the corresponding IO-Link process input data via the data mapping.
Note: Each port has its own input signals. It is not allowed to enter a signal from another port in the process data mapping.
 
–
Each individual binary input can be configured so that its state is logically inverted internally.