Analog output configuration
Selection and configuration of the inverter's internal analog values for output via IO-Link.
Details
Analog values of internal parameters can be sent to IO-Link process output data. Each analog output can be assigned an internal analog value of the inverter.
–
2 analog outputs are available for each IO-Link port.
–
For each analog output there is a parameter object that can be assigned to the corresponding IO-Link process output data via the data mapping.
Note: Each port has its own output signals. It is not allowed to enter a signal from another port in the process data mapping.
Note: Each port has its own output signals. It is not allowed to enter a signal from another port in the process data mapping.
–
The analog values can have a data length of 2 ... 32 bit.
–
A scaling can be parameterized for the analog values: