Basic setting and options

Parameter
Address
Name / setting range / [default setting]
Information
0x24A0:010
IO-Link master: SMI access
["0"]
0x24A1:011
IO-Link port 1: Vendor ID
0 ... [0] ... 65535
0x24A1:012
IO-Link port 1: Device ID
0 ... [0] ... 16777215
0x24A1:013
IO-Link port 1: Validation method
0
No check
1
Type compatible
0x24A1:014
IO-Link port 1: Backup method
0
No data storage
1
Backup and restore
2
Restore
0x24A1:015
IO-Link port 1: Revision ID
0
No check
16
Revision V1.0
17
Revision V1.1
0x24A1:016
IO-Link port 1: Cycle time
0.0 ... [0.0] ... 6553.5 ms
If set to "0", the fastest possible time is set that is supported by the IO-Link master or the IO-Link device.
–
Fastest possible cycle time IO-Link master: 2 ms
 
0x24A1:017
IO-Link port 1: Process data handling in case of error
0
Keep last data
1
Clear data
0x24A1:047
IO-Link port 1: Error response
Selection of the response when an error occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33217 | 0x81C1 - IO-Link port 1 error
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A1:048
IO-Link port 1: Warning response
Selection of the response when a warning occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33221 | 0x81C5 - IO-Link port 1 warning
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A2:011
IO-Link port 2: Vendor ID
0 ... [0] ... 65535
0x24A2:012
IO-Link port 2: Device ID
0 ... [0] ... 16777215
0x24A2:013
IO-Link port 2: Validation method
0
No check
1
Type compatible
0x24A2:014
IO-Link port 2: Backup method
0
No data storage
1
Backup and restore
2
Restore
0x24A2:015
IO-Link port 2: Revision ID
0
No check
16
Revision V1.0
17
Revision V1.1
0x24A2:016
IO-Link port 2: Cycle time
0.0 ... [0.0] ... 6553.5 ms
If set to "0", the fastest possible time is set that is supported by the IO-Link master or the IO-Link device.
–
Fastest possible cycle time IO-Link master: 2 ms
 
0x24A2:017
IO-Link port 2: Process data handling in case of error
0
Keep last data
1
Clear data
0x24A2:047
IO-Link port 2: Error response
Selection of the response when an error occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33218 | 0x81C2 - IO-Link port 2 error
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A2:048
IO-Link port 2: Warning response
Selection of the response when a warning occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33222 | 0x81C6 - IO-Link port 2 warning
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A3:011
IO-Link port 3: Vendor ID
0 ... [0] ... 65535
0x24A3:012
IO-Link port 3: Device ID
0 ... [0] ... 16777215
0x24A3:013
IO-Link port 3: Validation method
0
No check
1
Type compatible
0x24A3:014
IO-Link port 3: Backup method
0
No data storage
1
Backup and restore
2
Restore
0x24A3:015
IO-Link port 3: Revision ID
0
No check
16
Revision V1.0
17
Revision V1.1
0x24A3:016
IO-Link port 3: Cycle time
0.0 ... [0.0] ... 6553.5 ms
If set to "0", the fastest possible time is set that is supported by the IO-Link master or the IO-Link device.
–
Fastest possible cycle time IO-Link master: 2 ms
 
0x24A3:017
IO-Link port 3: Process data handling in case of error
0
Keep last data
1
Clear data
0x24A3:047
IO-Link port 3: Error response
Selection of the response when an error occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33219 | 0x81C3 - IO-Link port 3 error
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A3:048
IO-Link port 3: Warning response
Selection of the response when a warning occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33223 | 0x81C7 - IO-Link port 3 warning
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A4:011
IO-Link port 4: Vendor ID
0 ... [0] ... 65535
0x24A4:012
IO-Link port 4: Device ID
0 ... [0] ... 16777215
0x24A4:013
IO-Link port 4: Validation method
0
No check
1
Type compatible
0x24A4:014
IO-Link port 4: Backup method
0
No data storage
1
Backup and restore
2
Restore
0x24A4:015
IO-Link port 4: Revision ID
0
No check
16
Revision V1.0
17
Revision V1.1
0x24A4:016
IO-Link port 4: Cycle time
0.0 ... [0.0] ... 6553.5 ms
If set to "0", the fastest possible time is set that is supported by the IO-Link master or the IO-Link device.
–
Fastest possible cycle time IO-Link master: 2 ms
 
0x24A4:017
IO-Link port 4: Process data handling in case of error
0
Keep last data
1
Clear data
0x24A4:047
IO-Link port 4: Error response
Selection of the response when an error occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33220 | 0x81C4 - IO-Link port 4 error
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x24A4:048
IO-Link port 4: Warning response
Selection of the response when a warning occurs at the IO-Link port or IO-Link device.
Associated event ID:
–
33224 | 0x81C8 - IO-Link port 4 warning
 
0
No response
11
Information
12
Warning
16
Trouble
23
Fault > inverter disabled
0x401E:001
IO-Link: Encoder position value
-2147483648 ... [0] ... 2147483647