0x24A1:001
|
IO-Link port 1: Current vendor ID
|
|
|
0x24A1:002
|
IO-Link port 1: Current device ID
|
|
0x24A1:003
|
IO-Link port 1: Product name
|
|
0x24A1:004
|
IO-Link port 1: Firmware version
|
|
0x24A1:005
|
IO-Link port 1: Serial number
|
|
0x24A1:006
|
IO-Link port 1: Product ID
|
|
0x24A1:021
|
IO-Link port 1: Communication status
|
|
0
|
NO_DEVICE
|
|
1
|
DEACTIVATED
|
|
2
|
PORT_DIAG
|
|
3
|
PREOPERATE
|
|
4
|
OPERATE
|
|
5
|
DI_C/Q
|
|
6
|
DO_C/Q
|
|
254
|
POWER_PORT_OFF
|
|
255
|
NOT_AVAILABLE
|
|
0x24A1:022
|
IO-Link port 1: Current cycle time
|
|
0x24A1:023
|
IO-Link port 1: RPDO data length
|
|
0x24A1:024
|
IO-Link port 1: Received RPDO data
|
The data starts with the last mapping entry and ends with the first mapping entry.
|
|
0x24A1:025
|
IO-Link port 1: TPDO data length
|
|
|
0x24A1:026
|
IO-Link port 1: Transmitted TPDO data
["0"]
|
The data starts with the last mapping entry and ends with the first mapping entry.
If "Override output data" is activated in subindex 27, the process output data can be entered manually here.
|
|
0x24A1:027
|
IO-Link port 1: Enable TPDO data
|
|
|
0
|
No action
|
|
20
|
Force output data
|
|
0x24A1:028
|
IO-Link port 1: Status PDO data
|
Status is bit-coded:
–
Bit 0: Process input data valid
–
Bit 1: Process output data valid
|
|
Bit 0
|
RPDO not valid
|
|
|
Bit 1
|
TPDO not valid
|
|
0x24A1:029
|
IO-Link port 1: SDCI protocol
|
Display of the SDCI protocol version.
|
|
0x24A1:030
|
IO-Link port 1: Transmission rate
|
|
|
0
|
Not detected
|
|
1
|
COM1
|
|
2
|
COM2
|
|
3
|
COM3
|
|
0x24A1:049
|
IO-Link port 1: Diagnostic data length
|
Display of the number of existing diagnostic entries.
|
|
0x24A1:050
|
IO-Link port 1: Diagnostic entry 0
|
Meaning:
–
EventCode (Masking 0x0000FFFF)
–
Instance (Masking 0x00070000): 4 = Application
–
Source (Masking 0x00080000): 0 = Device, 1 = Master/Port
–
Type (Masking 0x00300000): 1 = Notification, 2 = Warning, 3 = Error
–
Mode (Masking 0x00C00000): 1 = Single shot, 2 = Disappears, 3 = Appears
|
|
0x24A1:051
|
IO-Link port 1: Diagnostic entry 1
|
|
0x24A1:052
|
IO-Link port 1: Diagnostic entry 2
|
|
0x24A1:053
|
IO-Link port 1: Diagnostic entry 3
|
|
0x24A1:054
|
IO-Link port 1: Diagnostic entry 4
|
|
0x24A1:055
|
IO-Link port 1: Diagnostic entry 5
|
|
0x24A1:056
|
IO-Link port 1: Diagnostic entry 6
|
|
0x24A1:057
|
IO-Link port 1: Diagnostic entry 7
|
|
0x24A1:058
|
IO-Link port 1: Diagnostic entry 8
|
|
0x24A1:059
|
IO-Link port 1: Diagnostic entry 9
|
|
0x24A2:001
|
IO-Link port 2: Current vendor ID
|
|
|
0x24A2:002
|
IO-Link port 2: Current device ID
|
|
0x24A2:003
|
IO-Link port 2: Product name
|
|
0x24A2:004
|
IO-Link port 2: Firmware version
|
|
0x24A2:005
|
IO-Link port 2: Serial number
|
|
0x24A2:006
|
IO-Link port 2: Product ID
|
|
0x24A2:021
|
IO-Link port 2: Communication status
|
|
0
|
NO_DEVICE
|
|
1
|
DEACTIVATED
|
|
2
|
PORT_DIAG
|
|
3
|
PREOPERATE
|
|
4
|
OPERATE
|
|
5
|
DI_C/Q
|
|
6
|
DO_C/Q
|
|
254
|
POWER_PORT_OFF
|
|
255
|
NOT_AVAILABLE
|
|
0x24A2:022
|
IO-Link port 2: Current cycle time
|
|
0x24A2:023
|
IO-Link port 2: RPDO data length
|
|
0x24A2:024
|
IO-Link port 2: Received RPDO data
|
The data starts with the last mapping entry and ends with the first mapping entry.
|
|
0x24A2:025
|
IO-Link port 2: TPDO data length
|
|
|
0x24A2:026
|
IO-Link port 2: Transmitted TPDO data
["0"]
|
The data starts with the last mapping entry and ends with the first mapping entry.
If "Override output data" is activated in subindex 27, the process output data can be entered manually here.
|
|
0x24A2:027
|
IO-Link port 2: Enable TPDO data
|
|
|
0
|
No action
|
|
20
|
Force output data
|
|
0x24A2:028
|
IO-Link port 2: Status PDO data
|
Status is bit-coded:
–
Bit 0: Process input data valid
–
Bit 1: Process output data valid
|
|
Bit 0
|
RPDO not valid
|
|
|
Bit 1
|
TPDO not valid
|
|
0x24A2:029
|
IO-Link port 2: SDCI protocol
|
Display of the SDCI protocol version.
|
|
0x24A2:030
|
IO-Link port 2: Transmission rate
|
|
|
0
|
Not detected
|
|
1
|
COM1
|
|
2
|
COM2
|
|
3
|
COM3
|
|
0x24A2:049
|
IO-Link port 2: Diagnostic data length
|
Display of the number of existing diagnostic entries.
|
|
0x24A2:050
|
IO-Link port 2: Diagnostic entry 0
|
Meaning:
–
EventCode (Masking 0x0000FFFF)
–
Instance (Masking 0x00070000): 4 = Application
–
Source (Masking 0x00080000): 0 = Device, 1 = Master/Port
–
Type (Masking 0x00300000): 1 = Notification, 2 = Warning, 3 = Error
–
Mode (Masking 0x00C00000): 1 = Single shot, 2 = Disappears, 3 = Appears
|
|
0x24A2:051
|
IO-Link port 2: Diagnostic entry 1
|
|
0x24A2:052
|
IO-Link port 2: Diagnostic entry 2
|
|
0x24A2:053
|
IO-Link port 2: Diagnostic entry 3
|
|
0x24A2:054
|
IO-Link port 2: Diagnostic entry 4
|
|
0x24A2:055
|
IO-Link port 2: Diagnostic entry 5
|
|
0x24A2:056
|
IO-Link port 2: Diagnostic entry 6
|
|
0x24A2:057
|
IO-Link port 2: Diagnostic entry 7
|
|
0x24A2:058
|
IO-Link port 2: Diagnostic entry 8
|
|
0x24A2:059
|
IO-Link port 2: Diagnostic entry 9
|
|
0x24A3:001
|
IO-Link port 3: Current vendor ID
|
|
|
0x24A3:002
|
IO-Link port 3: Current device ID
|
|
0x24A3:003
|
IO-Link port 3: Product name
|
|
0x24A3:004
|
IO-Link port 3: Firmware version
|
|
0x24A3:005
|
IO-Link port 3: Serial number
|
|
0x24A3:006
|
IO-Link port 3: Product ID
|
|
0x24A3:021
|
IO-Link port 3: Communication status
|
|
0
|
NO_DEVICE
|
|
1
|
DEACTIVATED
|
|
2
|
PORT_DIAG
|
|
3
|
PREOPERATE
|
|
4
|
OPERATE
|
|
5
|
DI_C/Q
|
|
6
|
DO_C/Q
|
|
254
|
POWER_PORT_OFF
|
|
255
|
NOT_AVAILABLE
|
|
0x24A3:022
|
IO-Link port 3: Current cycle time
|
|
0x24A3:023
|
IO-Link port 3: RPDO data length
|
|
0x24A3:024
|
IO-Link port 3: Received RPDO data
|
The data starts with the last mapping entry and ends with the first mapping entry.
|
|
0x24A3:025
|
IO-Link port 3: TPDO data length
|
|
|
0x24A3:026
|
IO-Link port 3: Transmitted TPDO data
["0"]
|
The data starts with the last mapping entry and ends with the first mapping entry.
If "Override output data" is activated in subindex 27, the process output data can be entered manually here.
|
|
0x24A3:027
|
IO-Link port 3: Enable TPDO data
|
|
|
0
|
No action
|
|
20
|
Force output data
|
|
0x24A3:028
|
IO-Link port 3: Status PDO data
|
Status is bit-coded:
–
Bit 0: Process input data valid
–
Bit 1: Process output data valid
|
|
Bit 0
|
RPDO not valid
|
|
|
Bit 1
|
TPDO not valid
|
|
0x24A3:029
|
IO-Link port 3: SDCI protocol
|
Display of the SDCI protocol version.
|
|
0x24A3:030
|
IO-Link port 3: Transmission rate
|
|
|
0
|
Not detected
|
|
1
|
COM1
|
|
2
|
COM2
|
|
3
|
COM3
|
|
0x24A3:049
|
IO-Link port 3: Diagnostic data length
|
Display of the number of existing diagnostic entries.
|
|
0x24A3:050
|
IO-Link port 3: Diagnostic entry 0
|
Meaning:
–
EventCode (Masking 0x0000FFFF)
–
Instance (Masking 0x00070000): 4 = Application
–
Source (Masking 0x00080000): 0 = Device, 1 = Master/Port
–
Type (Masking 0x00300000): 1 = Notification, 2 = Warning, 3 = Error
–
Mode (Masking 0x00C00000): 1 = Single shot, 2 = Disappears, 3 = Appears
|
|
0x24A3:051
|
IO-Link port 3: Diagnostic entry 1
|
|
0x24A3:052
|
IO-Link port 3: Diagnostic entry 2
|
|
0x24A3:053
|
IO-Link port 3: Diagnostic entry 3
|
|
0x24A3:054
|
IO-Link port 3: Diagnostic entry 4
|
|
0x24A3:055
|
IO-Link port 3: Diagnostic entry 5
|
|
0x24A3:056
|
IO-Link port 3: Diagnostic entry 6
|
|
0x24A3:057
|
IO-Link port 3: Diagnostic entry 7
|
|
0x24A3:058
|
IO-Link port 3: Diagnostic entry 8
|
|
0x24A3:059
|
IO-Link port 3: Diagnostic entry 9
|
|
0x24A4:001
|
IO-Link port 4: Current vendor ID
|
|
|
0x24A4:002
|
IO-Link port 4: Current device ID
|
|
0x24A4:003
|
IO-Link port 4: Product name
|
|
0x24A4:004
|
IO-Link port 4: Firmware version
|
|
0x24A4:005
|
IO-Link port 4: Serial number
|
|
0x24A4:006
|
IO-Link port 4: Product ID
|
|
0x24A4:021
|
IO-Link port 4: Communication status
|
|
0
|
NO_DEVICE
|
|
1
|
DEACTIVATED
|
|
2
|
PORT_DIAG
|
|
3
|
PREOPERATE
|
|
4
|
OPERATE
|
|
5
|
DI_C/Q
|
|
6
|
DO_C/Q
|
|
254
|
POWER_PORT_OFF
|
|
255
|
NOT_AVAILABLE
|
|
0x24A4:022
|
IO-Link port 4: Current cycle time
|
|
0x24A4:023
|
IO-Link port 4: RPDO data length
|
|
0x24A4:024
|
IO-Link port 4: Received RPDO data
|
The data starts with the last mapping entry and ends with the first mapping entry.
|
|
0x24A4:025
|
IO-Link port 4: TPDO data length
|
|
|
0x24A4:026
|
IO-Link port 4: Transmitted TPDO data
["0"]
|
The data starts with the last mapping entry and ends with the first mapping entry.
If "Override output data" is activated in subindex 27, the process output data can be entered manually here.
|
|
0x24A4:027
|
IO-Link port 4: Enable TPDO data
|
|
|
0
|
No action
|
|
20
|
Force output data
|
|
0x24A4:028
|
IO-Link port 4: Status PDO data
|
Status is bit-coded:
–
Bit 0: Process input data valid
–
Bit 1: Process output data valid
|
|
Bit 0
|
RPDO not valid
|
|
|
Bit 1
|
TPDO not valid
|
|
0x24A4:029
|
IO-Link port 4: SDCI protocol
|
Display of the SDCI protocol version.
|
|
0x24A4:030
|
IO-Link port 4: Transmission rate
|
|
|
0
|
Not detected
|
|
1
|
COM1
|
|
2
|
COM2
|
|
3
|
COM3
|
|
0x24A4:049
|
IO-Link port 4: Diagnostic data length
|
Display of the number of existing diagnostic entries.
|
|
0x24A4:050
|
IO-Link port 4: Diagnostic entry 0
|
Meaning:
–
EventCode (Masking 0x0000FFFF)
–
Instance (Masking 0x00070000): 4 = Application
–
Source (Masking 0x00080000): 0 = Device, 1 = Master/Port
–
Type (Masking 0x00300000): 1 = Notification, 2 = Warning, 3 = Error
–
Mode (Masking 0x00C00000): 1 = Single shot, 2 = Disappears, 3 = Appears
|
|
0x24A4:051
|
IO-Link port 4: Diagnostic entry 1
|
|
0x24A4:052
|
IO-Link port 4: Diagnostic entry 2
|
|
0x24A4:053
|
IO-Link port 4: Diagnostic entry 3
|
|
0x24A4:054
|
IO-Link port 4: Diagnostic entry 4
|
|
0x24A4:055
|
IO-Link port 4: Diagnostic entry 5
|
|
0x24A4:056
|
IO-Link port 4: Diagnostic entry 6
|
|
0x24A4:057
|
IO-Link port 4: Diagnostic entry 7
|
|
0x24A4:058
|
IO-Link port 4: Diagnostic entry 8
|
|
0x24A4:059
|
IO-Link port 4: Diagnostic entry 9
|