Binary output configuration
Selection and configuration of the inverter's internal binary values for output via IO-Link.
Details
Individual bits of the IO-Link process output data can be mapped to internal variables, so-called "binary outputs". An internal status signal of the inverter can be assigned to each binary output.
–
8 binary outputs are available for each IO-Link port.
–
For each binary output there is a parameter object that can be assigned to the corresponding IO-Link process output data via the data mapping.
Note: Each port has its own output signals. It is not allowed to enter a signal from another port in the process data mapping.
Note: Each port has its own output signals. It is not allowed to enter a signal from another port in the process data mapping.
–
Each individual binary output can be configured so that its state is logically inverted internally.